Purpose
Biochemical and histopathological properties of renal tissues were reported to be affected by both radiofrequency electromagnetic fields (RF-EMF) and ionizing radiation. The radiation-induced changes in the kidney, including the serum levels of blood urea nitrogen (BUN) and creatinine (Cr), could lead to adverse health outcomes such as chronic kidney disease. These complications signify the importance of the research in this field. Thus, in this study, the effects of ionizing and non-ionizing radiations, as well as their combination, were assessed by evaluating the alteration in BUN, Cr, and histopathological changes in kidney tissue.
Materials and Methods
Ninety-six male Wistar rats were randomly divided into six groups and were exposed to either 900/1800MHz (mobile phone) or 2.4 GHz RF-EMF (Wi-Fi) radiation for 14 days, 8Gy x-ray, or their combination. Sera were collected from 2 mL of rat blood, then BUN and Cr levels were determined. Also, renal samples were stained with hematoxylin and eosin and evaluated histopathologically.
Results
Both BUN and Cr levels raised non-significantly after exposure to 8 Gy x-rays. Moreover, all measurements in the samples of x-ray groups were in borderline or higher than normal values. The BUN levels of control, Wi-Fi, x-ray, and Wi-Fi+x-ray groups were not significantly different. However, Cr levels in the Wi-Fi group were significantly higher than those of the controls, and BUN to Cr ratio levels were significantly lower than those of the controls. Also, tubular atrophy and vessel wall thickening were associated with these exposures.
Conclusion
Exposure to 900/1800MHz, 2400 MHz EMF can alter the kidney function. However, pre-exposure to 900/1800MHz EMF could modulate the acute adverse effects of lethal x-ray dose, which addresses the adaptive response in the kidney.
AbstractBackground: Ionizing radiation has an indispensable role in diagnostic radiology and clinical treatments. Apparently, medical exposure in diagnostic radiology pertains to be the preeminent man-made source of radiation.Objective: The aim of the present scientific study is to calculate the Entrance Surface Dose (ESD) and Effective Dose (ED) in digital radiography in Mazandaran province.Materials and methods: The study was performed on 3600 patients in digital X-ray rooms 15 hospitals and the required data were collected from two age groups (10>15 years and adults) in each projection. Based on the results of this study, ESD and ED were calculated for skull (PA), skull (lateral), cervical spine (AP), cervical spine (lateral), chest (PA), chest (lateral), abdomen (AP), lumbar spine (AP), lumbar spine (lateral), pelvis (AP), thoracic spine (AP) and thoracic spine (lateral) examinations. It was calculated using PCXMC software (version 2.0).Results: In this study, mean ESDs for the 10-15 year group varied from 0.97±0.21 mGy to 3.62±1.38 mGy for chest (PA) and lumbar spine (lateral), respectively. For the adult group varied from 1.05±0.31 to 3.85±1.44 for cervical spine (AP) and lumbar spine (lateral), respectively. And also ED value was from in the range of 10.40 µSv to 378.46 µSv for skull (PA) 10-15 year group and abdomen adults, respectivelyConclusion: This survey revealed a significant variation in the radiation dose of digital radiology examinations among hospitals in Mazandaran province. Application of a dose reference level (DRL) could be an optimization procedure for reducing the patient’s dose in Mazandaran province.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.