OBJECTIVEWe estimate the effect size of hypoglycemia risk reduction on closed-loop control (CLC) versus open-loop (OL) sensor-augmented insulin pump therapy in supervised outpatient setting.RESEARCH DESIGN AND METHODSTwenty patients with type 1 diabetes initiated the study at the Universities of Virginia, Padova, and Montpellier and Sansum Diabetes Research Institute; 18 completed the entire protocol. Each patient participated in two 40-h outpatient sessions, CLC versus OL, in randomized order. Sensor (Dexcom G4) and insulin pump (Tandem t:slim) were connected to Diabetes Assistant (DiAs)—a smartphone artificial pancreas platform. The patient operated the system through the DiAs user interface during both CLC and OL; study personnel supervised on site and monitored DiAs remotely. There were no dietary restrictions; 45-min walks in town and restaurant dinners were included in both CLC and OL; alcohol was permitted.RESULTSThe primary outcome—reduction in risk for hypoglycemia as measured by the low blood glucose (BG) index (LGBI)—resulted in an effect size of 0.64, P = 0.003, with a twofold reduction of hypoglycemia requiring carbohydrate treatment: 1.2 vs. 2.4 episodes/session on CLC versus OL (P = 0.02). This was accompanied by a slight decrease in percentage of time in the target range of 3.9–10 mmol/L (66.1 vs. 70.7%) and increase in mean BG (8.9 vs. 8.4 mmol/L; P = 0.04) on CLC versus OL.CONCLUSIONSCLC running on a smartphone (DiAs) in outpatient conditions reduced hypoglycemia and hypoglycemia treatments when compared with sensor-augmented pump therapy. This was accompanied by marginal increase in average glycemia resulting from a possible overemphasis on hypoglycemia safety.
OBJECTIVEThe Pediatric Artificial Pancreas (PedArPan) project tested a children-specific version of the modular model predictive control (MMPC) algorithm in 5-to 9-yearold children during a camp.
RESEARCH DESIGN AND METHODSA total of 30 children, 5-to 9-years old, with type 1 diabetes completed an outpatient, open-label, randomized, crossover trial. Three days with an artificial pancreas (AP) were compared with three days of parent-managed sensoraugmented pump (SAP).
RESULTSOvernight time-in-hypoglycemia was reduced with the AP versus SAP, median (25 th -75 th percentiles): 0.0% (0.0-2.2) vs. 2.2% (0.0-12.3) (P 5 0.002), without a significant change of time-in-target, mean: 56.0% (SD 22.5) vs. 59.7% (21.2) (P 5 0.430), but with increased mean glucose 173 mg/dL (36) vs. 150 mg/dL (39) (P 5 0.002). Overall, the AP granted a threefold reduction of time-in-hypoglycemia (P < 0.001) at the cost of decreased time-in-target, 56.8% (13.5) vs. 63.1% (11.0) (P 5 0.022) and increased mean glucose 169 mg/dL (23) vs. 147 mg/dL (23) (P < 0.001).
CONCLUSIONSThis trial, the first outpatient single-hormone AP trial in a population of this age, shows feasibility and safety of MMPC in young children. Algorithm retuning will be performed to improve efficacy.Only three artificial pancreas (AP) trials have focused on the prepubertal population so far: two single-hormone AP studies, performed inpatient for less than 1 day (1,2) and a recent dual-hormone AP study, performed in a camp for 5 days (3). Here we report the first outpatient single-hormone AP trial focusing on 5-to 9-year-old children.Data were collected in the Pediatric Artificial Pancreas (PedArPan) camp, where sensor-augmented pump (SAP) therapy was compared with the modular model predictive control algorithm (MMPC) (4,5), running on the wearable platform Diabetes Assistant (DiAs) (6).
OBJECTIVEAfter testing of a wearable artificial pancreas (AP) during evening and night (E/N-AP) under free-living conditions in patients with type 1 diabetes (T1D), we investigated AP during day and night (D/N-AP) for 1 month.
RESEARCH DESIGN AND METHODSTwenty adult patients with T1D who completed a previous randomized crossover study comparing 2-month E/N-AP versus 2-month sensor augmented pump (SAP) volunteered for 1-month D/N-AP nonrandomized extension. AP was executed by a model predictive control algorithm run by a modified smartphone wirelessly connected to a continuous glucose monitor (CGM) and insulin pump. CGM data were analyzed by intention-to-treat with percentage time-in-target (3.9-10 mmol/L) over 24 h as the primary end point.
RESULTSTime-in-target (mean 6 SD, %) was similar over 24 h with D/N-AP versus E/N-AP: 64.7 6 7.6 vs. 63.6 6 9.9 (P = 0.79), and both were higher than with SAP: 59.7 6 9.6 (P = 0.01 and P = 0.06, respectively). Time below 3.9 mmol/L was similarly and significantly reduced by D/N-AP and E/N-AP versus SAP (both P < 0.001). SD of blood glucose concentration (mmol/L) was lower with D/N-AP versus E/N-AP during whole daytime: 3.2 6 0.6 vs. 3.4 6 0.7 (P = 0.003), morning: 2.7 6 0.5 vs. 3.1 6 0.5 (P = 0.02), and afternoon: 3.3 6 0.6 vs. 3.5 6 0.8 (P = 0.07), and was lower with D/N-AP versus SAP over 24 h: 3.1 6 0.5 vs. 3.3 6 0.6 (P = 0.049). Insulin delivery (IU) over 24 h was higher with D/N-AP and SAP than with E/N-AP: 40.6 6 15.5 and 42.3 6 15.5 vs. 36.6 6 11.6 (P = 0.03 and P = 0.0004, respectively).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.