Drill material and design, number of uses, depth and drilling load applied appear to influence bone temperature variations during implant site preparation. Drilling depth was a predominant factor in bone temperature increase. Both drills can be used up to 50 times without producing harmful temperatures to bone tissue or severe signs of wear and deformation.
Aims: This study aims to relate bone density in Hounsfield units (Hu) with the primary implant stability measured by insertion torque (Ncm) and resonance frequency analysis (ISQ). Materials and Methods: Ten patients were included in this study. A total of 54 implant sites were provided from 10 computerized tomography scans. The computerized tomography scan was used for the preoperative evaluation of bone density for each patient. The bone mean density around planned implants was determined with Physioplanet TM software. Bone quality according resistance to drilling, insertion torque and resonance frequency measurements were recorded. Results: A statistically significant relationship was observed between bone quality density and location with ISQ values. Conclusions: This research demonstrates a strong relationship between the bone density values from computerized tomography and the location in the maxillaries. A correlation exists between bone quality, according to the Lekholm & Zarb classification, and Hu computerized tomography values. The primary implant stability measured with resonance frequency analysis depends on bone density values, bone quality and implant location.
Various techniques are described in the literature, either by crestal or lateral approach. Sinus augmentation has a high percentage of success, but presents a number of intraoperative and postoperative complications. The most frequent complication is the Schneiderian membrane perforation with a percentage of perforations between 11% and 56% according to authors. The aim of this study is to describe another membrane approach technique for the sinus lateral wall osteotomy that minimizes the risk of Schneiderian membrane perforation. We present a case of a 50 year old patient attended the University Dental Clinic (UDC) of International University of Catalonia for implant and crown treatment due to the loss of a right maxillary first molar. To insert an implant in position 1.6 a computerized tomography (CT) was requested to determine with greater accuracy the quantity of residual crestal bone. It showed a height of 5 mm and width of 8 mm. The lateral osteotomy was performed with a (SLA KIT® -Neobiotech) trephine mounted in the same implant handpiece with which the field for the implant and the implant itself were prepared. It can be concluded that in the case described, the use of trephine drills of the SLA system mounted in a handpiece allows better access to lateral approach due to its perpendicular position relative to the sinus wall minimizing the membrane perforation risk.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.