Purpose: This review aimed to determine (1) performance and training characteristics such as training intensity distribution (TID), volume, periodization, and methods in highly trained/elite distance runners and (2) differences in training volume and TID between event distances in highly trained/elite distance runners. Methods: A systematic review of the literature was carried out using the PubMed/MEDLINE, Scopus, and Web of Science databases. Results: Ten articles met the inclusion criteria. Highly trained/elite distance runners typically follow a pyramidal TID approach, characterized by a decreasing training volume from zone 1 (at or below speed at first ventilatory/lactate threshold [LT]) to zone 2 (between speeds associated with either both ventilatory thresholds or 2 and 4 mmol·L−1 LTs [vLT1 and vLT2, respectively]) and zone 3 (speed above vVT2/vLT2). Continuous-tempo runs or interval training sessions at vLT2 in zone 2 (ie, medium and long aerobic intervals) and those in zone 3 (ie, anaerobic or short-interval training) were both used at least once per week each in elite runners, and they were used to increase the number of either vLT2 or z3 sessions to adopt either a pyramidal or a polarized approach, respectively. More pyramidal- and polarized-oriented approaches were used by marathoners and 1500-m runners, respectively. Conclusions: Highly trained and elite middle- and long-distance runners are encouraged to adopt a traditional periodization pattern with a hard day–easy day basis, consisting in a shift from a pyramidal TID used during the preparatory and precompetitive periods toward a polarized TID during the competitive period.
A breakpoint in a portable near-infrared spectroscopy (NIRS) derived deoxygenated haemoglobin (deoxy[Hb]) signal during an incremental VO2max running test has been associated with the second ventilatory threshold (VT2) in healthy participants. Thus, the aim was to examine the association between this breakpoint (NIRS) and VT2 in well-trained runners. Gas exchange and NIRS data were collected during an incremental VO2max running test for 10 well-trained runners. The breakpoint calculated in oxygen saturation (StO2) and the VT2 were determined and compared in terms relative to %VO2max, absolute speed, VO2, and maximum heart rate (HRmax). There were no significant differences (p>0.05) between the breakpoint in StO2 and VT2 relative to %VO2max (87.00±6.14 and 88.28 ± 3.98 %), absolute speed (15.70±1.42 and 16.10±1.66 km·h−1), VO2 (53.71±15.17 and 54.66±15.57 ml·kg−1·min−1), and%HRmax (90.90±4.17 and 91.84±3.70%). There were large and significant correlations between instruments relative to%VO2max (r=0.68, p<0.05), absolute speed (r=0.86, p<0.001), VO2 (r=0.86, p<0.001), and %HRmax (r=0.69; p<0.05). A Bland and Altman analysis of agreement between instruments resulted in a mean difference of − 1.27±4.49%, −0.40±0.84 km·h−1,−0.90±3.07 ml·kg−1·min−1, and − 0.94±3.14 for %VO2max, absolute speed, VO2, and %HRmax, respectively. We conclude that a portable NIRS determination of the StO2 breakpoint is comparable with VT2 using gas exchange and therefore appropriate for use in determining exercise training above VT2 intensity. This is the first study to analyze the validity with the running mode using a NIRS portable device.
This study aimed to address the effects of increased longitudinal bending stiffness (LBS) on running economy (RE) and running biomechanics. A systematic search on four electronic databases (Pubmed, WOS, Medline and Scopus) was conducted on 26 May 2021. Twelve studies met the inclusion criteria and were included. Standardised mean difference with 95% confidence intervals (CI) between footwear with increased LBS vs. non-increased LBS conditions and effect sizes were calculated. To assess the potential effects of moderator variables (type and length plate, increased LBS, shoe mass and running speed) on the main outcome variable (i.e. RE), subgroup analyses were performed. Increased LBS improved RE (SMD = −0.43 [95% CI −0.58, −0.28], Z = 5.60, p < 0.001) compared to non-increased LBS. Significant increases of stride length (SMD = 0.29 [95% CI 0.10, 0.49], Z = 2.93, p = 0.003) and contact time (SMD = 0.17 [95% CI 0.03, 0.31], Z = 2.32, p = 0.02) were found when LBS was increased. RE improved to a greater degree at higher running speeds with footwear with increased LBS. RE improved 3.45% with curve plate compared to no-plate condition without improvements with flat plate shoes. When shoe mass was matched between footwear with increased LBS vs. non-increased LBS conditions, RE improved (3.15%). However, when shoe mass was not controlled (experimental condition with ∼35 grams extra), a significant small improvement was found. These RE improvements appear along with an increase of stride length and contact time. Shoe mass, type of plate (flat or curve) and running speed should be taken into consideration when designing a shoe aimed at improving long-distance running performance. KEYWORDSCarbon-fibre plate; vaporfly; energy cost of running; performance Highlights. Shoes with relatively high longitudinal bending stiffness (but not very stiff) improve running economy compared to conventional shoes. . The oxygen cost reduction was influenced by the mass of the shoe, the type of plate and the running speed. . The running economy improvements appear along with an increase of stride length and contact time.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.