BackgroundHyaluronic acid (HA)-based devices are among the most popular filler agents for skin rejuvenation. One of the principal goals is the improvement in residence time of HA-based products, to increase their performance and reduce frequency of the treatment. So, understanding fillers, behavior after subcutaneous injection is a fundamental aspect for discovery and optimization of new products. Current in vivo approaches to detect/quantify injected HA fillers are not always well optimized or easy to apply.ObjectiveTo develop more efficacious and noninvasive diagnostic tools to make a quantitative evaluation of the degradation of fillers in a small animal model.Materials and methodsWe evaluated the residence time of different HA-based fillers, fluorescein-labeled and not, injected subcutaneously in mice. Volumes of fillers were monitored through high-frequency ultrasound (HF-US) method while fluorescence intensity through the well-established fluorescence living imaging method. To confirm the effectiveness of HF-US, obtained volumetric measurements were compared with fluorescence intensity values.ResultsBoth the presented methods revealed the same degradation kinetics for the tested products.ConclusionThe two used methods are fully comparable and quantitatively accurate. The presented approach has been proved to be noninvasive, sensitive, and reproducible.
The aim of this study was to investigate the performance and the reversibility of different classes of Hyaluronic Acid (HA) dermal fillers. We analysed 4 HA based fillers, belonging to 3 different chemical classes of products, commonly used in the field of wrinkles correction: linear HA 8 mg/mL (Viscoderm 0.8), thermically stabilized hybrid complexes of high and low molecular weight HA molecules at a concentration of 32 mg/mL and 45 mg/mL respectively (Profhilo and Profhilo Structura) and cross-linked HA 25 mg/mL (Aliaxin GP). Methods: The products were tested by a well-established animal model. The generated implants were analyzed through High-Frequency Ultrasound technology. Then, reversibility of the treatment was evaluated by enzymatic degradation kinetics studies, characterised by a combined approach of Carbazole assay and HP-SEC/TDA method. Results: Implants generated by linear HA 8 mg/mL remained detectable by ultrasound acquisition for 4 weeks, whereas those generated by injection of HA hybrid complex 32 mg/mL were detectable for 10 weeks. HA hybrid complex 45 mg/mL and crosslinked HA 25 mg/mL were detectable for 29 and at least 33 weeks, respectively. Enzymatic degradation kinetics studies demonstrated that the HA content in HA hybrid complex 45 mg/mL was almost completely depolymerized and homogeneous after 3 h of treatment. For cross-linked HA 25 mg/mL, 24 h of incubation are needed to obtain the same degree of depolymerization.
Conclusion:The study confirmed the ability of the experimental model to predict the behaviour of HA based dermal fillers in vivo and showed the innovative aspects of HA hybrid complex 45 mg/mL, that combines the high-safety profile, in terms of reversibility of the treatment, of the linear HA-based products with the durability of a high degree cross-linked gels, paving the way to the chance to be used for a wide range of applications in the field of aesthetic medicine.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.