Objectives: To assess the timeframe between tooth extraction and radiographically detectable socket cortication in humans. Methods:Two hundred and fifty patients with a CT scan ≤36 months after tooth extraction were included. First, three orthoradial multiplanar reconstruction slices, representing the major part of the extraction socket, were scored regarding the degree of bone healing as (i) healed, that is, complete/continuous cortication of the socket entrance, or (ii) non-healed. Thereafter, based on the results of all three slices, the stage of cortication of the extraction socket, as one unit, was classified as (i) non-corticated, that is, all three slices judged as non-healed, (ii) partially corticated, that is, 1 or 2 slices judged as non-healed, or (iii) completely corticated, that is, all three slices judged as healed. The possible effect of several independent parameters, that is, age, gender, timeframe between tooth extraction and CT scan, tooth type, extent of radiographic bone loss of the extracted tooth, tooth-gap type, smoking status, presence of any systemic disease, and medication intake, on cortication status was statistically evaluated.Results: Three to 6 months after tooth extraction, 27% of the sockets were judged as non-corticated and 53% were judged as partially corticated. After 9-12 months, >80% of the sockets were corticated, while some incompletely corticated sockets were detected up to 15 months after extraction. Each additional month after tooth extraction contributed significantly to a higher likelihood of a more advanced stage of cortication, while radiographic bone loss ≥75% significantly prolonged cortication time; no other independent variable had a significant effect. Conclusions:The results indicate a considerably long timeframe until complete cortication of an extraction socket, that is, 3-6 months after tooth extraction 3 of 4 sockets were still not completely corticated, and only after 9-12 months, complete cortication was observed in about 80% of the sockets. K E Y W O R D Scomputed tomography, cortical bone, cortication, socket entrance, socket healing, tooth extraction
Background: Maxillary sinus floor augmentation (MSFA) is a well-established and predictable augmentation method in severely resorbed maxillae. However, data on the vertical course of bone graft consolidation within the maxillary sinus are rare. The aim of the present study was to quantify the vertical distribution of new bone formation (nBF) in MSFA and to characterize the vertical gradient of bone graft consolidation. Methods: Eighty-five human sinus biopsies were harvested 6 ± 1 months after MSFA. Histological thin-ground sections were prepared and histomorphometrically analyzed. The volume of newly formed bone (nBV/TV) was measured in serial zones of 100 μm proceeding from the bottom of the sinus floor (SF) up to the apical top of the biopsy. The gradient of nBV/TV within the augmentation area was determined by the vertical distribution of nBV/TV along these zones. Results: In the premolar region, nBV/TV slightly declined from 20.4% in the zone adjacent to the SF to 17.7% at a distance of 8 mm. The gradient was steeper in the molar region: nBV/TV decreased from 18.7% to 12.8%. This decline was even more distinct when the volume fraction and the height of the residual bone of the SF were low. Conclusions: nBF follows a gradient from native bone of the SF towards the apical part of the augmentation area. The distance to primordial bone thus plays a critical role for bone regeneration in MSFA, particularly in the molar region.
Background. The inaccurate maxillomandibular relationship of virtual casts following alignment by the vestibular scan may result in intersection (intermesh penetration) between opposing dental arch surfaces. Intersection occurs at short interocclusal distances in the occlusal contact area (OCA) and may result in infra-occluded definitive restorations. The purpose of this clinical study was to compare initial (by the proprietary scanner software) and new alignments (by a standalone 3D software) of virtual casts regarding OCA and intersection failure. New alignments aimed to rectify intersections by refinement of occlusal contacts. Material and Methods. The virtual casts of 30 patients following digital and conventional impression-taking were analyzed, which were acquired for single implant restoration in the posterior site. Digital impressions were performed by both IOS 1 (3M True Definition) and IOS 2 (TRIOS 3), either as complete- or partial-arch scans, respectively. Mounted gypsum casts were digitized as complete-arch by a laboratory scanner (LS) in enabled and disabled mode to avoid intersection [LS (+)/LS (−)]. All virtual casts were newly aligned by a 3D software. The difference of the OCA and the area of intersection were calculated for initial and new alignments, using interocclusal distance ranges of 0–100 μm, 0–10 μm or <0 μm (=intersection). The difference of the OCA was compared using a linear mixed model. The distribution of occlusal contact points per modality and alignment was assessed independently by three observers and estimated by inter- and intraclass correlation (ICC) coefficients. Results. Virtual casts following initial alignment demonstrated intersections irrespective of the modality. The mean area of the intersection was most for IOS 2 (79.23 mm2), followed by IOS 1 (48.28 mm2), LS (−) (2.77 mm2), and LS (+) (2.01 mm2) in partial-arch scans. Complete-arch scans demonstrated an area of intersection of 70.63 mm2 for IOS 1 followed by 65.52 mm2 (IOS 2), 6.13 mm2 [LS (−)] and 2.76 mm2 [LS (+)]. Newly aligned scans showed no intersections. The overall distribution of occlusal contact points demonstrated moderate reliability (ICC 0.63). Good reliability could be observed (ICC 0.9) for LS (−) scans. Conclusions. Intersections in the area of occlusal contact points are a phenomenon restricted to virtual casts, which should be considered in CAD/CAM. Initial alignments of LS are less affected by this virtual phenomenon, and contact points may be more distinct according to their anatomic region compared to IOS. Furthermore, intersections can be rectified in a 3D software by adjustment of the maxillomandibular relationship.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.