Although over the last 20 years diffusion MRI has become an established technique with a great impact on health care and neurosciences, like any other MRI technique it remains subject to artifacts and pitfalls. In addition to common MRI artifacts, there are specific problems that one may encounter when using MRI scanner gradient hardware for diffusion MRI, especially in terms of eddy currents and sensitivity to motion. In this article we review those artifacts and pitfalls on a qualitative basis, and introduce possible strategies that have been developed to mitigate or overcome them.
Delivery of therapeutic or diagnostic agents to the brain is majorly hindered by the blood-brain barrier (BBB). Recently, many studies have demonstrated local and transient disruption of the BBB using low power ultrasound sonication combined with intravascular microbubbles. However, BBB opening and closure mechanisms are poorly understood, especially the maximum gap that may be safely generated between endothelial cells and the duration of opening of the BBB. Here, we studied BBB opening and closure under magnetic resonance (MR) guidance in a rat model. First, MR contrast agents (CA) of different hydrodynamic diameters (1 to 65 nm) were employed to estimate the largest molecular size permissible across the cerebral tissues. Second, to estimate the duration of the BBB opening, the CA were injected at various times post-BBB disruption (12 minutes to 24 hours). A T 1 mapping strategy was developed to assess CA concentration at the ultrasound (US) focal point. Based on our experimental data and BBB closure modeling, a calibration curve was obtained to compute the half closure time as a function of CA hydrodynamic diameter. These findings and the model provide an invaluable basis for optimal design and delivery of nanoparticles to the brain.
In the present work, the NMR properties of perfluorooctylbromide are revisited to derive a high-sensitivity fluorine MRI strategy. It is shown that the harmful effects of J-coupling can be eliminated by carefully choosing the bandwidth of the 180°pulses in a spin-echo sequence. The T 2 of the CF 3 resonance of the molecule is measured using a multispin-echo sequence and shown to dramatically depend on the interpulse delay. Following these observations, an optimized multispinecho imaging sequence is derived and compared with short TE/pulse repetition time gradient echo and chemical shift imaging sequences. The unparalleled sensitivity yielded by the multispin-echo sequence is promising for future applications, in particular for targeted contrast agents such as perfluorooctylbromide nanoparticles.
Object: A method is proposed for generating schemes of diffusion gradient orientations which allow the diffusion tensor to be reconstructed from partial data sets in clinical DT-MRI, should the acquisition be corrupted or terminated before completion because of patient motion. Materials and methods: A general energy-minimization electrostatic model was developed in which the interactions between orientations are weighted according to their temporal order during acquisition. In this report, two corruption scenarios were specifically considered for generating relatively uniform schemes of 18 and 60 orientations, with useful subsets of 6 and 15 orientations. The sets and subsets were compared to conventional sets through their energy, condition number and rotational invariance.Schemes of 18 orientations were tested on a volunteer. Results: The optimized sets were similar to uniform sets in terms of energy, condition number and rotational invariance, whether the complete set or only a subset was considered. Diffusion maps obtained in vivo were close to those for uniform sets whatever the acquisition time was. This was not the case with conventional schemes, whose subset uniformity was insufficient. Conclusion: With the proposed approach, sets of orientations responding to several corruption scenarios can be generated, which is potentially useful for imaging uncooperative patients or infants.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.