Classical marker-based roentgen stereophotogrammetric analysis (RSA) is an accurate method of measuring in vivo implant migration. A disadvantage of the method is the necessity of placing tantalum markers on the implant, which constitutes additional manufacturing and certification effort. Model-based RSA (MBRSA) is a method by which pose-estimation of geometric surface-models of the implant is used to detect implant migration. The placement of prosthesis markers is thus no longer necessary. The accuracy of the pose-estimation algorithms used depends on the geometry of the prosthesis as well as the accuracy of the surface models used. The goal of this study was thus to evaluate the experimental accuracy and precision of the MBRSA method for four different, but typical prosthesis geometries, that are commonly implanted. Is there a relationship existing between the accuracy of MBRSA and prosthesis geometries? Four different prosthesis geometries were investigated: one femoral and one tibial total knee arthroplasty (TKA) component and two different femoral stem total hip arthroplasty (THA) components. An experimental phantom model was used to simulate two different implant migration protocols, whereby the implant was moved relative to the surrounding bone (relative prosthesis-bone motion (RM)), or, similar to the double-repeated measures performed to assess accuracy clinically, both the prosthesis and the surrounding bone model (zero relative prosthesis-bone motion (ZRM)) were moved. Motions were performed about three translational and three rotational axes, respectively. The maximum 95% confidence interval (CI) for MBRSA of all four prosthesis investigated was better than -0.034 to 0.107 mm for in-plane and -0.217 to 0.069 mm for out-of-plane translation, and from -0.038 deg to 0.162 deg for in-plane and from -1.316 deg to 0.071 deg for out-of-plane rotation, with no clear differences between the ZRM and RM protocols observed. Accuracy in translation was similar between TKA and THA components, whereas rotational accuracy about the long axis of the hip stem THA components was worse than the TKA components. The data suggest that accuracy and precision of MBRSA seem to be equivalent to the classical marker-based RSA method, at least for the nonsymmetric implant geometries investigated in this study. The model-based method thus allows the accurate measurement of implant migration without requiring prosthesis markers, and thus presents new opportunities for measuring implant migration where financial or geometric considerations of marker placement have thus far been prohibitive factors.
BackgroundModel-based Roentgen Stereophotogrammetric Analysis (MBRSA) allows the accurate in vivo measurement of the relative motion between an implant and the surrounding bone (migration), using pose-estimation algorithms and three dimensional geometric surface models of the implant. The goal of this study was thus to investigate the effect of surface model resolution on the accuracy of the MBRSA method.MethodsFour different implant geometries (knee femoral and tibial components, and two different hip stems) were investigated, for each of which two reversed engineering (RE) models of differing spatial digitizing resolution were generated. Accuracy of implant migration measurement using MBRSA was assessed in dependence on surface model resolution using an experimental phantom-model set up.ResultsWhen using the lower quality RE models, the worst bias observed ranged from -0.048 to 0.037 mm, and -0.057 to 0.078 deg for translation and rotation respectively. For higher quality reverse engineering models, bias ranged from -0.042 to 0.048 mm, and -0.449 to 0.029 deg. The pair-wise comparisons of digitizing resolution (higher vs. lower quality) within the different implant type revealed significant differences only for the hip stems (p < 0.001).ConclusionThe data suggest that the application of lower resolution RE models for MBRSA is a viable alternative method for the in vivo measurement of implant migration, in particular for implants with non symmetrical geometries (total knee arthroplasty). Implants with larger length to width aspect ratio (total hip arthroplasty) may require high resolution RE models in order to achieve acceptable accuracy. Conversely, for some axis the bias for translation are clearly worse for translation, and are marginally better for rotations using the lower resolution RE models instead of the higher ones. However, performed box plots ranges were well within what has been reported in the literature. The observed lower accuracy and precision of the measurements for hip stem components for rotations about the superior-inferior direction is presumably the result of the nature of the MBRSA method. This well known effect within MBRSA for rotations about the axis of symmetry of axially-symmetric objects do not change the contour of the projected image to as large a degree as motion about a non-symmetric axes. It is not possible to detected this small motion as accurately using pose-estimation methods. This may affect the “higher” accuracy for the applied lower resolution RE models.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.