While computed tomography (CT) has long been used for medical applications and material inspection, its application field has recently been broadened to include industrial dimensional metrology. However, the accuracy of CT-based measurements remains yet largely uncertain. Not only are the measurements influenced by a number of factors and parameters like e.g. workpiece orientation, magnification, edge detection and so on, but also the calibration method matters greatly. This paper investigates the influence of these factors and parameters and the calibration method (rescaling and correction) on accuracy and repeatability of the measurements, using a test object with parallel grooves. The test object is also used to illustrate how more accurate CMM measurements can be used to calibrate CT measurements and to compare different calibration and compensation strategies.
Industrial x-ray computed tomography (CT) systems are being increasingly used as dimensional measuring machines. However, micron level accuracy is not always achievable, as of yet. The measurement accuracy is influenced by many factors, such as the workpiece properties, x-ray voltage, filter, beam hardening, scattering and calibration methods (Kruth et al 2011 CIRP Ann. Manuf. Technol. 60 821–42, Bartscher et al 2007 CIRP Ann. Manuf. Technol. 56 495–8, De Chiffre et al 2005 CIRP Ann. Manuf. Technol. 54 479–82, Schmitt and Niggemann 2010 Meas. Sci. Technol. 21 054008). Since most of these factors are mutually correlated, it remains challenging to interpret measurement results and to identify the distinct error sources. Since simulations allow isolating the different affecting factors, they form a useful complement to experimental investigations. Dewulf et al (2012 CIRP Ann. Manuf. Technol. 61 495–8) investigated the influence of beam hardening correction parameters on the diameter of a calibrated steel pin in different experimental set-ups. It was clearly shown that an inappropriate beam hardening correction can result in significant dimensional errors. This paper confirms these results using simulations of a pin surrounded by a stepped cylinder: a clear discontinuity in the measured diameter of the inner pin is observed where it enters the surrounding material. The results are expanded with an investigation of the beam hardening effect on the measurement results for both inner and outer diameters of the surrounding stepped cylinder. Accuracy as well as the effect on the uncertainty determination is discussed. The results are compared with simulations using monochromatic beams in order to have a benchmark which excludes beam hardening effects and x-ray scattering. Furthermore, based on the above results, the authors propose a case-dependent calibration artefact for beam hardening correction and edge offset determination. In the final part of the paper, the investigations are expanded with experiments of a new set-up that includes non-cylindrical features; the effectiveness of the proposed calibration artefact is also studied.
Coordinate measurement machine (CMM) probing techniques can involve direct mechanical contact (e.g., tactile probing) or diverse non-contact principles (e.g., laser line scan probing). For some applications, contact methods are not capable of measuring fast enough to ensure 100% quality controlled parts. A laser line scanning probe uses a laser triangulation-based method to acquire 3D measurement points on a workpiece relative to a sensor. Mounting the sensor in a 3D coordinate frame, e.g., in a CMM provides enough information to fully examine the workpiece. These techniques are most commonly exploited in medical industry and industries involving plate materials. A high data density and measurement speed are significant advantages when measuring free-form surfaces by laser line scanning, making the process much more time-efficient. However, high-precision geometrical features (such as cylinders, spheres, etc.) must be measured for locating and aligning the free-form shapes. The accuracy of the equipment therefore has to be assessed. Probe Maximum Permissible Error (MPEP) values below 10μm have been reported for cutting-edge laser line scanners. This paper compares the major influences on measurements on cylindrical features. First, the aspect-ratio limitations are considered by comparing two inherently different techniques. The stable inspection of reference features is important, while trying to maximize the spatial extent of the measured features. Second, the measurement method is analyzed in two ways: by using a limited sample of the features to increase stability and eliminate interference from neighboring features; by varying the number of scan tracks, which greatly affects the measurement time.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.