Cardiac resynchronisation therapy implantation was the procedure with the highest risk of complications requiring surgical revision. Complications were associated with substantial clinical consequences and a significant increase in the number and length of hospitalizations.
The results of this retrospective analysis show that, in order to prevent a recurrence of VVS in patients with a cardioinhibitory response to HUTT, dual-chamber CLS pacing was more effective than dual-chamber pacing with conventional algorithms for syncope prevention in preventing bradycardia-related syncope.
FAVALE, S., et al.: Sudden Death Due to Atrial Fibrillation in Hypertrophic Cardiomyopathy: A Predictable Event in a Young Patient.
This case refers to a 39‐year‐old woman with hypertrophic cardiomyopathy (HCM) and family history of sudden death (SD). In 1985, high rate atrial stimulation induced VF. In 1996 an ICD was implanted and she remained without arrhythmic events until November 2000 when the device reported one episode of atrial fibrillation degenerating into VF and terminated by the ICD. The VF induction mechanism recorded by the ICD was similar to that observed in 1985. The high incidence of atrial tachyarrhythmias in HCM renders cases like this at higher risk of SD. The predictive role of incremental atrial stimulation merits highlighting in future studies. (PACE 2003; 26[Pt. I]:637–639)
The "EGM width criterion" is a discrimination algorithm that was available in the last generation ICDs. It improved ventricular tachycardia detection by withholding inappropriate therapy deliveries in the presence of narrow QRS tachycardias. The accuracy of the algorithm depends on the optimal settings of the intracardiac EGM source, the "slew thresholds," and the "width threshold." The possible dependence of these parameters on body position may affect the detection efficacy. Whether these effects can be minimized by a proper choice of the electrode configuration used for signal analysis is still to be investigated. This study aimed to evaluate the stability of the slew threshold and width threshold obtained in the supine and orthostatic positions detected by the tip-to-ventricular coil and can-to-ventricular coil electrode configurations. Their time dependence was also evaluated at the 6-month follow-up. Fifty-eight patients who were recipients of an ICD (model Medtronic 7223cx and 7227cx) were included in the study. Changing from supine to orthostatic position caused a marked variation of slew and width thresholds (21.0 +/- 13.9 V/s and 10.1 +/- 9.6 ms, respectively) in 36% of patients with tip-to-ventricular coil and in 44% of patients with can-to-defibrillating coil (the mean slew threshold variation was in this case 17.6 +/- 15.8 V/s, while the mean width threshold variation was 18.8 +/- 21.0 ms). Width threshold variation was statistically significant (P < 0.02) with the latter electrode configuration. Slew thresholds settings changed between the 1- and 6-month follow-ups in the 75% of patients with can-to-defibrillating coil configuration and in 50% with tip-to-defibrillating coil. These time related variations were significantly larger with the tip-to-defibrillating coil configuration (P < 0.01). In conclusion, EGM width parameters may change between supine and orthostatic position and over time with tip-to-defibrillating coil configuration and can-to-defibrillating coil configuration. The former configuration was less sensitive to body position changes, but more sensitive to time related variations. These findings may be useful for optimal programming of the EGM width criterion, but if parameter programming based on these results can improve the discrimination specificity still needs to be investigated.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.