Disseminated thrombotic processes in the microcirculation are considered to be an important cause of multiple organ failure in septic patients. Fibrinolysis is one endogenous mechanism protecting the circulation from overwhelming thrombosis. Therefore, we looked for alterations of fibrinolytic parameters (tissue plasminogen activator (t-PA), tissue plasminogen activator inhibitor (PAI), D-dimer, euglobulin-clot-lysis-time (ECLT), plasminogen, alpha 2-antiplasmin) and of some coagulation parameters (prothrombin time, fibrinogen, platelets, antithrombin III, protein C, factor XII) in clearly defined septic patients and for the relations of these values to the severity of the disease (APACHE II-score). An increase in D-dimer and t-PA-antigen was registered in all patients, while factor XII and plasminogen were decreased, indicating an activated fibrinolysis. In contrast the systemic fibrinolytic capacity of the blood was strongly inhibited: t-PA-activity was not detectable, PAI-function was elevated, the ECLT was prolonged and alpha 2-antiplasmin was normal. Coagulation was moderately activated: the platelets, antithrombin III and protein C were decreased, the prothrombin time was prolonged and fibrinogen was normal. The changes in t-PA-antigen, PAI-function, factor XII, prothrombin time and antithrombin III were significantly related to the APACHE II-score of the patients. We conclude that the activation of coagulation is accompanied by an activation of fibrinolysis in the microcirculation, but that systemically the increased inhibitors of fibrinolysis (PAI, alpha 2-antiplasmin) induce a decrease of the fibrinolytic capacity of the blood. The severity of the disease determines the extent of the alterations.
The administration of AT III was safe and well-tolerated. It was followed by a 39 % reduction in 30-day all-cause mortality (NS). The reduction in mortality was accompanied by a considerably shorter stay in the ICU. Patients treated with AT III exhibited a better performance in overall severity of illness and organ failure scores (Acute Physiology and Chronic Health Evaluation II, multiple organ failure, organ system failure), which was noticeable soon after initiation of treatment. Patients treated with AT III demonstrated a better resolution of pre-existing organ failures and a lower incidence of new organ failures during the observation period. A meta-analysis comprising this and two other double-blind, placebo-controlled trials with AT III with a total of 122 patients suffering from severe sepsis confirms the positive trend. The results of the meta-analysis demonstrate a 22.9 % reduction in 30-day all-cause mortality in patients treated with AT III. Although still too small to be confirmative, the meta-analysis clearly points to the fact that a sufficiently powered phase III trial is warranted to prove whether AT III has a beneficial role in the treatment of severe sepsis.
These findings indicate that micro-CT is feasible for structural evaluation of the lung fine structure and its alterations during endotoxin-induced lung injury.
Clinical evidence of a septic process is most likely to be preceded by activation of the hemostatic system, the vascular endothelium, and the monocyte/macrophage system. IL-6 may have a regulatory function for hemostasis in inflammation. Laboratory monitoring could be helpful in deciding whether to start early intensive therapy in patients at risk for sepsis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.