A thermomechanical fatigue (TMF) test rig was developed consisting of the loading, heating, synchronizing, cooling and monitoring systems. Moreover, the specimen was particularly designed to provide adequate load-bearing capability at the blade tip in order to simulate the actual turbine blade loads in laboratory. TMF test on a single crystal nickel superalloy turbine blade was conducted. Then the specimen was segmented in a novel way to preserve the crack surface to investigate the TMF mechanism of the turbine blade. Visual examination together with the metallographic analysis indicated that the most severe TMF damage occurred at the pin-fin fillet on the suction side near the trailing edge. Furthermore, finite element simulation results were compared to the experiment, in which a viscoplastic constitutive model was employed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.