The main end points for sedation during endoscopy are patients' satisfaction, short duration of the procedure, and safety. During the last year, attention has focused on attempting to identify the "ideal" candidate for moderate sedation/analgesia and on the importance of providing the patient with appropriate information before the procedure. The increasing pressure to perform more procedures, reduce costs, and achieve shorter patient turnaround times has affected recent approaches to sedation during endoscopy, focusing attention on alternatives to pharmacological sedation such as providing relaxing music, using small-caliber endoscopes for unsedated peroral gastroscopy, and using magnetic endoscopic imaging to increase tolerance and reduce discomfort during colonoscopy. The results, however, have not been convincing. The role of benzodiazepines was discussed in some studies, highlighting the well-known effect of midazolam on postprocedural amnesia, its pharmacological profile and tolerability after intranasal spraying in healthy volunteers, and the efficacy and safety of this route of administration as an alternative to intravenous administration in diagnostic upper gastrointestinal endoscopy. The form of sedation for gastrointestinal endoscopy that has attracted great interest over the last year is the use of intravenous propofol, either alone or with concomitant benzodiazepines or opioids. As expected in view of the drug's known pharmacological properties, the quality of sedation was better and recovery time was shorter in patients treated with propofol. However, important questions involving the narrow therapeutic range and the mode of administration of propofol (by endoscopists or nurses, or by anesthesiologists) remain open. One important aspect of sedation procedures is prevention of cardiopulmonary complications. The use of electronic monitoring techniques, with a pulse oximeter, has been recommended as a standard procedure during digestive endoscopy; however, pulse oximetry no longer reflects the normal ventilatory functions and does not detect episodes of severe CO2 retention. CO2 monitoring by transcutaneous measurement - or better, by capnography - appears to be useful, as an alternative to pulse oximetry, as a measure of hypoventilation, and for detecting potentially important abnormalities in respiratory activity in patients undergoing sedation for gastrointestinal endoscopy. With regard to preparation for endoscopic procedures, several "ideal" formulas for bowel preparation have been presented. These include the use of sodium phosphate compounds as an alternative to polyethylene glycol electrolyte lavage solutions (PEG-ELS); however, the results so far have been conflicting. The best and most cost-effective bowel cleansing procedure for colonoscopy and sigmoidoscopy has yet to be established.
A new immunosensor for the determination of procalcitonin was developed. A sandwich assay format was implemented on a polymethylmetacrylate optical biochip, opportunely shaped in order to obtain several flow channels and potentially suitable for point of care testing applications. The sandwich format makes use of two new rat monoclonal antibodies. The capture antibody was covalently immobilised on the surface of the plastic chip, and the detection antibody was labelled with DY647 dye. Different combinations of capture and detection antibodies were investigated, and particular attention was devoted in order to avoid the non-specific adsorption. A limit of detection of 0.088 mg L(-1) was achieved within the working range of 0.28-50 mg L(-1) in buffer samples. The assay was also implemented in human serum, and 0.2 and 0.7-25 mg L(-1) were the attained limit of detection and working range, respectively.
A novel fluorescence-based optical platform for the interrogation of an optical biochip was designed and developed. The optical biochip was made of poly(methyl methacrylate) (PMMA) formed by two pieces of PMMA appropriately shaped in order to obtain four microchannels that are 500-microm wide and 400-microm high. The lower part includes the microchannels and the inlet and outlet for the fluidics, while the sensing biolayer was immobilized on the upper part. The optical signal comprised the fluorescence emitted by the biolayer, which was anisotropically coupled to the PMMA cover and suitably guided by the PMMA chip. The potentiality of the optical chip as a biosensor was investigated by means of a direct IgG/anti-IgG interaction carried out inside the flow channels. The mouse-IgG was covalently immobilized on the internal wall of the PMMA cover, and the Cy5-labelled anti-mouse IgG was used for the specific interaction. Several chemical treatments of the PMMA surface were investigated, poly(L: -lactic acid), Eudragit L100 and NaOH, in order to obtain the most effective distribution of carboxylic groups useful for the covalent immobilisation of the mouse-IgG. The treatment with Eudragit L100 was found to be the most successful. Limits of detection and quantification of 0.05 microg mL(-1) and 0.2 microg mL(-1), respectively, were obtained with the configuration described.
Severe infection and sepsis are a common, expensive, and frequently fatal conditions in critically ill patients. The sepsis diagnosis is not trivial, since it is an extremely complex chain of events involving inflammatory and anti-inflammatory processes, cellular reactions, and circulatory disorders. For these reasons, delay in diagnosis and initiation of drug treatments have shown to be crucial for this pathology. Moreover, a multitude of biomarkers has been proposed, many more than for other pathologies. In order to select optimal treatments for the highly heterogeneous group of sepsis patients and to reduce costs, novel multiplexed tools that better characterize the patient and his or her specific immune response are highly desired. In order to achieve the fundament of drastically improved multi-analyte detection and to attain low limits of detection in diagnostics, the area of point-of-care testing (POCT) technology is developing quickly, leading to the production of instruments, the reliability of which is continuously increasing. For this purpose, a selection of two biomarkers—C-reactive protein (CRP) and neopterin (NP)—was studied in this paper and a fluorescence-based integrated optical system, suitable for future POCT applications, was implemented that is capable of performing the simultaneous measurement of the two different biomarkers in replicate. A limit of detection of 10 and 2.1 µg L−1 was achieved for CRP and NP spiked in commercially available human serum, respectively. Moreover, measurements on both biomarkers were also performed on serum samples collected from septic patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.