Objective: To develop a simple clock drawing score system for patients with Alzheimer's disease, that correlates with the MMSE (Folstein Mini Mental Status Examination).1 Design: A retrospective analysis of 88 patients with the diagnosis of Alzheimer's disease Setting: Outpatient Memory Disorder Institute of a large community teaching hospital. Measurements: MMSE score and two different clock drawing ratings. The MMSE and the clock drawing scoring were performed by different raters. We present a “simple clock scoring system” and compared it with a previously published scoring system by Sunderland et al,2 referred to as the standard score system. Results: There is a strong correlation between the “new score system” and the standard scoring (Pearsons Correlation Coefficient r = 0.91, p < 0.001). However, when both systems were evaluated in a multivariate linear regression analysis, the “ simple score system “ was a significant predictor of Folstein MMSE (P < 0.01), while the standard scoring system was not. Conclusion: The “simple score system” is an easy to use, accurate predictor of the MMSE score, in patients with the diagnosis of Alzheimer's disease.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.