Objective: The mechanisms of radiation-induced DNA damage can be understood via the fundamental acquisition of knowledge through a combination of experiments and modeling. Currently, most biological experiments are performed by irradiating an entire cell population, whereas modeling of radiation-induced effects is usually performed via Monte Carlo simulations with track structure codes coupled to realistic DNA geometries of a single-cell nucleus. However, the difference in scale between the two methods hinders a direct comparison because the dose distribution in the cell population is not necessarily uniform owing to the stochastic nature of the energy deposition. Thus, this study proposed the MINAS TIRITH tool to model the distribution of radiation-induced DNA damage in a cell population. Approach: The proposed method is based on precomputed databases of microdosimetric parameters and DNA damage distributions generated using the Geant4-DNA Monte Carlo Toolkit. First, a specific energy z was assigned to each cell of an irradiated population for a particular absorbed dose D_abs, following microdosimetric formalism. Then, each cell was assigned a realistic number of DNA damage events according to the specific energy z, respecting the stochastic character of its occurrence. Main results: This study validated the MINAS TIRITH tool by comparing its results with those obtained using the Geant4-DNA track structure code and a Geant4-DNA based simulation chain for DNA damage calculation. The different elements of comparison indicated consistency between MINAS TIRITH and the Monte Carlo simulation in case of the dose distribution in the population and the calculation of the amount of DNA damage. Significance: MINAS TIRITH is a new approach for the calculation of radiation-induced DNA damage at the cell population level that facilitates reasonable simulation times compared to those obtained with track structure codes. Moreover, this tool enables a more direct comparison between modeling and biological experimentation.
After large-scale radiation accidents where many individuals are suspected to be exposed to ionizing radiation, biological and physical retrospective dosimetry assays are important tools to aid clinical decision making by categorizing individuals into unexposed/minimally, moderately or highly exposed groups. Quality-controlled inter-laboratory comparisons of simulated accident scenarios are regularly performed in the frame of the European legal association RENEB (Running the European Network of Biological and Physical retrospective Dosimetry) to optimize international networking and emergency readiness in case of large-scale radiation events. In total 33 laboratories from 22 countries around the world participated in the current RENEB inter-laboratory comparison 2021 for the dicentric chromosome assay. Blood was irradiated in vitro with X rays (240 kVp, 13 mA, ∼75 keV, 1 Gy/min) to simulate an acute, homogeneous whole-body exposure. Three blood samples (no. 1: 0 Gy, no. 2: 1.2 Gy, no. 3: 3.5 Gy) were sent to each participant and the task was to culture samples, to prepare slides and to assess radiation doses based on the observed dicentric yields from 50 manually or 150 semi-automatically scored metaphases (triage mode scoring). Approximately two-thirds of the participants applied calibration curves from irradiations with γ rays and about 1/3 from irradiations with X rays with varying energies. The categorization of the samples in clinically relevant groups corresponding to individuals that were unexposed/minimally (0–1 Gy), moderately (1–2 Gy) or highly exposed (>2 Gy) was successfully performed by all participants for sample no. 1 and no. 3 and by ≥74% for sample no. 2. However, while most participants estimated a dose of exactly 0 Gy for the sham-irradiated sample, the precise dose estimates of the samples irradiated with doses >0 Gy were systematically higher than the corresponding reference doses and showed a median deviation of 0.5 Gy (sample no. 2) and 0.95 Gy (sample no. 3) for manual scoring. By converting doses estimated based on γ-ray calibration curves to X-ray doses of a comparable mean photon energy as used in this exercise, the median deviation decreased to 0.27 Gy (sample no. 2) and 0.6 Gy (sample no. 3). The main aim of biological dosimetry in the case of a large-scale event is the categorization of individuals into clinically relevant groups, to aid clinical decision making. This task was successfully performed by all participants for the 0 Gy and 3.5 Gy samples and by 74% (manual scoring) and 80% (semi-automatic scoring) for the 1.2 Gy sample. Due to the accuracy of the dicentric chromosome assay and the high number of participating laboratories, a systematic shift of the dose estimates could be revealed. Differences in radiation quality (X ray vs. γ ray) between the test samples and the applied dose effect curves can partly explain the systematic shift. There might be several additional reasons for the observed bias (e.g., donor effects, transport, experimental conditions or the irradiation setup) and the analysis of these reasons provides great opportunities for future research. The participation of laboratories from countries around the world gave the opportunity to compare the results on an international level.
No abstract
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.