Summary Background Whole-body magnetic resonance imaging (WB-MRI) could be an alternative to multi-modality staging of non-small-cell lung cancer (NSCLC), but its diagnostic accuracy, effect on staging times, number of tests needed, cost, and effect on treatment decisions are unknown. We aimed to prospectively compare the diagnostic accuracy and efficiency of WB-MRI-based staging pathways with standard pathways in NSCLC. Methods The Streamline L trial was a prospective, multicentre trial done in 16 hospitals in England. Eligible patients were 18 years or older, with newly diagnosed NSCLC that was potentially radically treatable on diagnostic chest CT (defined as stage IIIb or less). Exclusion criteria were severe systemic disease, pregnancy, contraindications to MRI, or histologies other than NSCLC. Patients underwent WB-MRI, the result of which was withheld until standard staging investigations were complete and the first treatment decision made. The multidisciplinary team recorded its treatment decision based on standard investigations, then on the WB-MRI staging pathway (WB-MRI plus additional tests generated), and finally on all tests. The primary outcome was difference in per-patient sensitivity for metastases between standard and WB-MRI staging pathways against a consensus reference standard at 12 months, in the per-protocol population. Secondary outcomes were difference in per-patient specificity for metastatic disease detection between standard and WB-MRI staging pathways, differences in treatment decisions, staging efficiency (time taken, test number, and costs) and per-organ sensitivity and specificity for metastases and per-patient agreement for local T and N stage. This trial is registered with the International Standard Randomised Controlled Trial registry, number ISRCTN50436483, and is complete. Findings Between Feb 26, 2013, and Sept 5, 2016, 976 patients were screened for eligibility. 353 patients were recruited, 187 of whom completed the trial; 52 (28%) had metastasis at baseline. Pathway sensitivity was 50% (95% CI 37–63) for WB-MRI and 54% (41–67) for standard pathways, a difference of 4% (−7 to 15, p=0·73). No adverse events related to imaging were reported. Specificity did not differ between WB-MRI (93% [88–96]) and standard pathways (95% [91–98], p=0·45). Agreement with the multidisciplinary team's final treatment decision was 98% for WB-MRI and 99% for the standard pathway. Time to complete staging was shorter for WB-MRI (13 days [12–14]) than for the standard pathway (19 days [17–21]); a 6-day (4–8) difference. The number of tests required was similar WB-MRI (one [1–1]) and standard pathways (one [1–2]). Mean per-patient costs were £317 (273–361) for WBI-MRI and £620 (574–666) for standard pathways. Interpretation WB-MRI staging pathways have similar accuracy to standard pathways, and reduce the staging time and costs. Funding UK National Institute...
Background Whole-body MRI (WB-MRI) could be an alternative to multimodality staging of colorectal cancer, but its diagnostic accuracy, effect on staging times, number of tests needed, cost, and effect on treatment decisions are unknown. We aimed to prospectively compare the diagnostic accuracy and efficiency of WB-MRI-based staging pathways with standard pathways in colorectal cancer. Methods The Streamline C trial was a prospective, multicentre trial done in 16 hospitals in England. Eligible patients were 18 years or older, with newly diagnosed colorectal cancer. Exclusion criteria were severe systemic disease, pregnancy, contraindications to MRI, or polyp cancer. Patients underwent WB-MRI, the result of which was withheld until standard staging investigations were complete and the first treatment decision made. The multidisciplinary team recorded its treatment decision based on standard investigations, then on the WB-MRI staging pathway (WB-MRI plus additional tests generated), and finally on all tests. The primary outcome was difference in per-patient sensitivity for metastases between standard and WB-MRI staging pathways against a consensus reference standard at 12 months, in the per-protocol population. Secondary outcomes were difference in per-patient specificity for metastatic disease detection between standard and WB-MRI staging pathways, differences in treatment decisions, staging efficiency (time taken, test number, and costs), and per-organ sensitivity and specificity for metastases and per-patient agreement for local T and N stage. This trial is registered with the International Standard Randomised Controlled Trial registry, number ISRCTN43958015, and is complete.
Lay open of low and high anal fistulas is effective and associated with a similar, predictable rate of minor sphincter disturbance, amounting to a third to one quarter of patients with mild leakage of flatus and mucus. Patients with high fistulas can be cured, but when a surgeon is in doubt, a second opinion at an expert centre should be sought before definitive intervention.
The negative correlation between transfer constant (reflecting tumour blood flow and microvessel permeability) with CD31 expression is paradoxical. DCE MRI methods for assessing tissue vascularity correlate poorly with histological markers of angiogenesis and hypoxia, suggesting that DCE MRI does not simply reflect static histological vascular properties in patients with rectal cancer.
The cMDT-MODe instrument can be reliably used to prospectively assess decision making in the multidisciplinary management of colorectal patients. By systematically quantifying the quality of a colorectal cancer tumor board, we can identify areas for improving practice so as to optimize decision making for cancer care.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.