Microfluidic devices have been fabricated on poly(methyl methacrylate) substrates by two independent imprinting techniques. First-generation devices were fabricated using a small-diameter wire to create an impression in plastics softened by low-temperature heating. The resulting devices are limited to only simple linear channel designs but are readily produced at low cost. Second-generation devices with more complex microchannel arrangements were fabricated by imprinting the plastic substrates using an inverse three-dimensional image of the device micromachined on a silicon wafer. This micromachined template may be used repeatedly to generate devices reproducibly. Fluorescent analtyes were used to demonstrate reproducible electrophoretic injections. An immunoassay was also performed in an imprinted device as a demonstration of future applications.
New analytical methods using fluorescence detection are becoming increasingly quantitative and require easy-to-use material standards for fluorometer qualification and method validation. NIST is responding to this need by developing and producing such standards. Reported here is the first step in this process, which is to qualify a research-grade fluorescence spectrometer for measuring true fluorescence spectra of reference material candidates. "True" spectra are defined here as those with fluorescence intensity, either relative or absolute as required, and wavelength both being reported with high accuracy and known precision, after wavelength has been calibrated and corrections for excitation intensity and detection system response have been applied. The uncertainties determined in relative and absolute intensity-corrected fluorescence spectra using both calibrated source (CS)- and calibrated detector (CD)-based methods were compared. The CS-based method gave uncertainties, typically about +/-5% for relative spectral correction, that were about half that of the CD-based method for determining both relative and absolute spectral correction factors. Absolute spectral correction factors can be determined using either method without knowing the optical geometry of the instrument. The absolute spectral correction factors were found to have much larger uncertainties than the corresponding relative correction factors with uncertainties for the CS-based method of +/-10% to +/-15% being typical and +/-20% or more not being uncommon, particularly for excitation and emission wavelengths below 400 nm. Uncertainties arising from detection system nonlinearity and instrument polarization ratios were also explored.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.