The study aims to provide an up-to-date systematic review and meta-analysis comparing radiological and functional outcomes of total knee arthroplasty (TKA) and unicompartmental knee arthroplasty (UKA) using either robotic assistance or conventional methods from the latest assemblage of evidence. This study was conducted according to PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) and MOOSE (Meta-analysis of Observational Studies in Epidemiology) guidelines. All studies in PubMed, EMBASE, Medline, and Cochrane that reported radiological and functional outcomes after TKA or UKA with either robotic or conventional methods were included in the review. Selected endpoints for random effects, pairwise meta-analysis included operative details, radiological outcomes (mechanical axis, component angle deviation, and outliers), and functional outcomes (American Knee Society Score, Knee Society Function Score, revision and complication rate, range of motion (ROM), Hospital for Special Surgery score, and Western Ontario and McMaster Universities Osteoarthritis Index). A total of 23 studies comprising 2,765 knees were included from the initial search. Robot-assisted TKA and UKA were associated with significantly better component angle alignment accuracy (low-to-high quality evidence) at the cost of significantly greater operation time. Robot-assisted UKA was found to have significantly better short-term functional outcomes compared with conventional UKA (moderate-to-high quality evidence). Robot-assisted TKA, however, did not exhibit significantly better short- and midterm subjective knee outcome scores compared with its conventional counterpart (high-quality evidence). Robot-assisted TKA and UKA were associated with nonstatistically significant improved ROM and lesser rates of revision. Robot-assisted total and unicompartmental knee arthroplasty leads to better radiological outcomes, with no significant differences in mid- and long-term functional outcomes compared with conventional methods for the former. Larger prospective studies with mid- and long-term outcomes are required to further substantiate findings from the present study.
Additive manufacturing of stainless steel is becoming increasingly accessible, allowing for the customisation of structure and surface characteristics; there is little guidance for the post-processing of these metals. We carried out this study to ascertain the effects of various combinations of post-processing methods on the surface of an additively manufactured stainless steel 316L lattice. We also characterized the nature of residual surface particles found after these processes via energy-dispersive X-ray spectroscopy. Finally, we measured the surface roughness of the post-processing lattices via digital microscopy. The native lattices had a predictably high surface roughness from partially molten particles. Sandblasting effectively removed this but damaged the surface, introducing a peel-off layer, as well as leaving surface residue from the glass beads used. The addition of either abrasive polishing or electropolishing removed the peel-off layer but introduced other surface deficiencies making it more susceptible to corrosion. Finally, when electropolishing was performed after the above processes, there was a significant reduction in residual surface particles. The constitution of the particulate debris as well as the lattice surface roughness following each post-processing method varied, with potential implications for clinical use. The work provides a good base for future development of post-processing methods for additively manufactured stainless steel.
The 'cement in cement' technique for revision hip arthroplasty has become popular in recent years, particularly in relation to polished taper stems. Since 2006 a short Exeter stem with 44 mm offset has been available specifically for this purpose. We report a fracture of such a stem in the absence of trauma 5 years after the revision procedure. The patient had a BMI of 27.8 and the proximal cement mantle gave good support to the stem. The fracture initiated and propagated from the introducer hole on the shoulder of the prosthesis. Macroscopically there was no defect in this area. This may be an unusual case of fatigue failure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.