Purpose:
To investigate the mechanism of action of the Tetraflex (Lenstec Kellen KH-3500) accommodative intraocular lens (IOL).
Methods:
Thirteen eyes of eight patients implanted with the Tetraflex accommodating IOL for at least 2 years underwent assessment of their objective amplitude-of-accommodation by autorefraction, anterior chamber depth and pupil size with optical coherence tomography, and IOL flexure with aberrometry, each viewing a target at 0.0 to 4.00 diopters of accommodative demand.
Results:
Pupil size decreased by 0.62±0.41 mm on increasing accommodative demand, but the Tetraflex IOL was relatively fixed in position within the eye. The ocular aberrations of the eye changed with increased accommodative demand, but not in a consistent manner among individuals. Those aberrations that appeared to be most affected were defocus, vertical primary and secondary astigmatism, vertical coma, horizontal and vertical primary and secondary trefoil, and spherical aberration.
Conclusions:
Some of the reported near vision benefits of the Tetraflex accommodating IOL appear to be due to changes in the optical aberrations because of the flexure of the IOL on accommodative effort rather than forward movement within the capsular bag.
There is increasing interest in the effects of reactive oxygen species ('free radicals') in ageing, both in the body overall and specifically in the eye. Cataract and age-related macular degeneration (AMD) are two major causes of blindness, with cataract accounting for 48 per cent of world blindness and AMD accounting for 8.7 per cent. Both cataract and AMD affect an older population (over 50 years of age) and while cataract is largely treatable provided resources are available, AMD is a common cause of untreatable, progressive visual loss. There is evidence that AMD is linked to exposure to short wavelength electromagnetic radiation, which includes ultraviolet, blue and violet wavelengths. The ageing crystalline lens provides some protection to the posterior pole because, as it yellows with age, its spectral absorption increasingly blocks the shorter wavelengths of light. Ultraviolet blocking intraocular lenses (IOLs) have been the standard of care for many years but a more recent trend is to include blue-blocking filters based on theoretical benefits. As these filters absorb part of the visible spectrum, they may affect visual function. This review looks at the risks and the benefits of filtering out short wavelength light in pseudophakic patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.