The solubility of triclocarban in ultrapure water and in several natural aqueous solutions is influenced by several environmental factors. In this study the variation of temperature, pH, ionic strength and concentration of the organic matter over the solubility of triclocarban was analysed. The results show that the solubility of triclocarban increases by increasing the contact time, longer than the time of equilibrium and the temperature. It is less influenced by the variations of pH and strongly influenced by the variation of ionic strength and by the natural organic matter into the studied aqueous matrices.
Biocidal products are substances or mixtures of several substances, used to combat harmful organisms for human or animal health. Substances with antibacterial effects include quaternary ammonium salts, such as benzalkonium chloride (BAC), didecyl chloride (DDAC), etc. Benzalkonium chloride (BAC) is a compound of the class of quaternary ammonium compounds (QAC) used as a cationic surfactant in personal hygiene, cosmetic and skin disinfection products [1]. BAC is a mixture of alkylbenzyldimethylammonium chlorides [C6H5CH2N(CH3)2RCl], in which R = C12, C14, C16, C18 are the main compounds, and the antibacterial effects being given by the alkyl chain length and the quaternary ammonium groups [1,2].In this study we compare two methods of analysis for quantitative determination: chemical titration [3] and liquid chromatography (HPLC-UV) [4]. Chemical titration is an iodometric method in a strongly acidic medium, in which the 0.05M potassium iodate solution is used as titrant (titration with extracted end point) [3]. HPLC determinations were performed using an Agilent 1100 Series HPLC, equipped with a binary pump, a degasser, an autosampler and a spectrophotometric detector in UV-Vis, and Agilent Chemstation software was used for data acquisition and analysis. Chromatographic parameters were injection volume, 10 μL; analysis time, 25 min; a Zorbax Eclipse XDB-C18 column (5 μm, 4.6 mm × 150 mm); and flow rate, 1.5 mL/min, isocratic conditions 20:80 A:B (v/v), where A = 0.4 M/L NaCl solution and B = methanol [4]. BAC monitoring was performed at a wavelength of 210 nm with the help of a UV-Vis spectrophotometric detector. The identification was performed by comparing the retention time of the analyzed compound with the retention time of the standard solution. Confirmation of the presence of BAC alkylic homologues, prior to quantitative determination, was performed using the mass spectrometry detection technique with a time-of-flight detector (TOF LC/MS).As a measure of selectivity, for calculating the degree of recovery, the standard method of addition was applied. As a measure of selectivity, the degree of recovery determined by the standard addition method was used. For the titrimetric method we studied the influence of the presence of possible interferences different from those of the QAC class, such as ethyl and isopropyl alcohols, glutaraldehyde, non-ionic surfactants, stabilizers, etc. Regarding the HPLC-UV method, we were particularly interested in the selectivity with respect to other quaternary ammonium salts, such as didecyldimethylammonium chloride (DDAC) and cationic surfactants.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.