In the current study, we explored the magnetic hyperthermia performance of condensed–clustered magnetic iron oxide nanoparticles (MIONs) in the range of 400 kHz to 1.1 MHz at low field amplitudes. The strong interparticle interactions, present in such systems, can influence the hyperthermia power produced by MIONs. Herein, the heat dependence, as an increasing function of frequency, with a fixed magnetic field strength of 3 mT is recorded, revealing a direct relationship between the two physical quantities and a high heating efficiency for the condensed–clustered MIONs. In particular, the specific loss power (SLP) (or specific absorption rate [SAR]) parameter, which is the ratio of the heat power in watts produced per nanoparticle mass in grams, is linear to a good degree to the oscillating frequency with a step of roughly 30 W/g per 100 kHz increase. In addition, all the measurements were within the safety limits proposed by Hergt and Dutz criterion of H f ≤ 5 × 109A/ms for clinical application of magnetic fluid hyperthermia (MFH). Finally, the measured data of temperature vs. time at each frequency were interpreted in terms of simple thermodynamic arguments, thus extracting useful thermodynamic parameters for the heat power generated by the condensed–clustered MIONs.
In this work, we present a simple and efficient method for the preparation of hemin-modified SnO2 films on Metglas ribbon substrates for the development of a sensitive magneto-electrochemical sensor for the determination of H2O2. The SnO2 films were prepared at low temperatures, using a simple hydrothermal method, compatible with the Metglas surface. The SnO2 film layer was fully characterized by X-ray Diffraction (XRD), Scanning Electron Microscopy (SEM), photoluminescence (PL) and Fourier Transform-Infrared spectroscopy (FT-IR). The properties of the films enable a high hemin loading to be achieved in a stable and functional way. The Hemin/SnO2-Metglas system was simultaneously used as a working electrode (WE) for cyclic voltammetry (CV) measurements and as a magnetoelastic sensor excited by external coils, which drive it to resonance and interrogate it. The CV scans reveal direct reduction and oxidation of the immobilized hemin, as well as good electrocatalytic response for the reduction of H2O2. In addition, the magnetoelastic resonance (MR) technique allows the detection of any mass change during the electroreduction of H2O2 by the immobilized hemin on the Metglas surface. The experimental results revealed a mass increase on the sensor during the redox reaction, which was calculated to be 767 ng/μM. This behavior was not detected during the control experiment, where only the NaH2PO4 solution was present. The following results also showed a sensitive electrochemical sensor response linearly proportional to the concentration of H2O2 in the range 1 × 10−6–72 × 10−6 M, with a correlation coefficient of 0.987 and detection limit of 1.6 × 10−7 M. Moreover, the Hemin/SnO2-Metglas displayed a rapid response (30 s) to H2O2 and exhibits good stability, reproducibility and selectivity.
In the current work, to identify the bending mode harmonics, 30 microns thin magnetoelastic ribbons made of metallic glass are embedded inside 6 mm thick PLA plastic cantilever beams made by 3-D printing. This is possible because the ribbons are of magnetoelastic nature and thus change their mechanical state inducing a corresponding change in their magnetic state. The ribbons are placed at four different depths, starting with zero depth at the beam’s external surface all the way inside to the beam’s mid-plane. This technique is capable of detecting seven harmonics, and remarkably, these frequencies remain the same within a marginal error of 1% for all the depths. The amplitude of the modes drops with the increase in depth but is still strong enough, except at the midplane, to be used as a sensing signal. The harmonics spectrum is the unique signature of the structure’s state; this is a proof of concept that in a contactless fashion, the embedded ribbons provide useful information about the mechanical health of a structure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.