Background
The use of disinfectants, such as disinfectant towelettes, play an important role pathogen transmission that can lead to healthcare-associated infections (HAIs). However, the efficacy of disinfectant towelette products when tested under realistic use conditions is understudied. A test model was designed to replicate realistic wiping conditions. The objective of this study was to determine the impact of varied contact time on disinfectant towelette efficacy under these conditions.
Methods
Five product types were tested against Staphylococcus aureus (ATCC 6538) and Pseudomonas aeruginosa (ATCC 15442) at five contact times (30 s, one min, two min, three min, and 10 min) on hard, non-porous laminate templates to determine the impact of contact time on disinfectant towelette efficacy when tested under realistic use.
Results
Product type had a significant impact on the efficacy of disinfectant towelettes when tested under conditions reflective of realistic use. The effect of contact time was limited and no differences in efficacy were seen at a contact time of one min compared with the other contact times tested. Only one disinfectant towelette product achieved a 5-log reduction under the tested conditions.
Conclusion
Efficacy of disinfectant towelettes was primarily impacted by product type when applied in a model designed to replicate realistic use in which only a limited effect of contact time was observed. There is a need for further investigation into which factors have the greatest impact on disinfectant towelette efficacy when applied in clinical settings.
Background
Disinfectant towelettes are increasingly being used as a means to prevent transmission of clinically important pathogens which could lead to healthcare-associated infections (HAIs). However, the efficacy of disinfectant towelette products when tested under realistic use conditions is understudied. A test model was designed to replicate realistic wiping conditions. The objective of this study was to determine the impact of varied contact time on disinfectant towelette efficacy under these conditions.
Methods
Five product types were tested against Staphylococcus aureus (ATCC 6538) and Pseudomonas aeruginosa (ATCC 15,442) at five contact times (30 s, one min, two min, three min, and 10 min) on hard, non-porous laminate templates to determine the impact of contact time on disinfectant towelette efficacy when tested under realistic use.
Results
Product type had a significant impact on the efficacy of disinfectant towelettes when tested under conditions reflective of realistic use. The effect of contact time was limited and no differences in efficacy were seen at a contact time of one min compared with the other contact times tested. Only one disinfectant towelette product achieved a mean 5-log reduction under the tested conditions.
Conclusion
Efficacy of disinfectant towelettes was primarily impacted by product type when applied in a model designed to replicate realistic use in which only a limited effect of contact time was observed. There is a need for further investigation into which factors have the greatest impact on disinfectant towelette efficacy when applied in clinical settings.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.