A moisture-insensitive optical fingerprint scanner (FPS) that is based on polarization resolved in-finger light is proposed and realized. Incident visible light, which is selectively fed to a fingerprint sample via a polarization beam splitter (PBS), is deemed to be partially scattered backward by tissues associated with the skin of the finger. The backscattered light is mostly index-guided in the ridge comprising the fingerprint, which has a higher refractive index, and is drastically dispersed in the valley, which is typically filled with water or air and so has a lower index. However, when light reflects directly off the surface of the finger skin, it fundamentally prevents the scanned image from being determined. The proposed FPS produces bright and dark intensity patterns that are alternately created on the surface of the PBS and correspond to the ridges and valleys, respectively. Thus, this method can especially distinguish between a fake synthetic fingerprint and a genuine fingerprint due to its use of in-finger scattered light. The scanner has been rigorously designed by carrying out ray-optic simulations depending on the wavelength, with tissue-induced scattering taken into account. The device was constructed by incorporating a wire-grid type PBS in conjunction with visible LED sources, including blue, green and red. The scanner adopting a blue LED, which exhibits the strongest light scattering, resulted in the best fingerprint image, enabling enhanced fidelity under the wet and dry situations. Finally, a fake synthetic fingerprint could be successfully discriminated.
A refractometric sensor resorting to a vertically coupled polymeric microdisk resonator was demonstrated, estimating the refractive index (RI) of an analyte by monitoring the resonant wavelength shift in its transfer characteristics. The disk resonator was especially overlaid with a high RI TiO2 film, thereby reinforcing the interaction of the evanescent field of its guided mode with the analyte. The sensitivity of the sensor was theoretically and experimentally confirmed to be enhanced by adjusting the overlay thickness. The fabricated sensor provided the maximum sensitivity of approximately 294 nm/RIU (refractive index unit) with the 40-nm-thick overlay, which is equivalent to an improvement of 150% compared with the case without the overlay.
A birefringence measurement system is introduced to get high phase resolution for detection of low contents of biochemicals. By using a fixed quarter-wave plate and a rotating polarizer, the phase difference between two orthogonal polarizations is transformed into phase delay of output sinusoidal signal. Analyzing the output phase, birefringence change could be detected with a phase noise of 0.14 degrees. As well as the birefringence measurement system, an optical evanescent waveguide sensor was developed. A rib-type silica waveguide overlaid with TiO2 film was fabricated, and a developed birefringence measurement technique was employed in evaluating a refractive index change on waveguide surface. For the fabricated waveguide with a 40-nm-thick TiO2 film, experiment results showed that the minimum detectable index change was 5.9x10(-7).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.