Cataract or refractive lens surgery, along with the implantation of multifocal intraocular lenses (MF-IOL), enables a complete range of functional far, near and intermediate vision. Refractive, diffractive and extended depth of focus (EDoF) or combination of these principles represent the technology used to obtain this multifocality. Aberrometry makes it possible to study the aberrations induced by MF-IOLs. Among the different optical principles available to measure ocular aberrations, pyramidal wavefront-based sensor (PWS) aberrometry shows the highest resolution with MF-IOLs. Retinal image quality measured by a PWS aberrometer differed significantly according to the technology of the implanted lens. Monofocal and diffractive lenses showed the highest values of far-distance retinal image quality, followed by refractive and EDoF lenses; however, retinal image quality analysed in diffractive lenses appears to be more dependent on residual refractive error. Considering this limitation, PWS-aberrometry could be used to compare diffractive lenses. Nevertheless, further studies are needed to provide additional information about the clinical retinal image quality of MF-IOLs and to help surgeons in the important preoperative selection of IOLs.
Background/Purpose Inverted Inner Limiting Membrane (ILM)-flap approach can fail in the treatment of Optic disc pit maculopathy (ODPM). We report a surgical technique involving human amniotic membrane (hAM) patch implant to treat unresolved ODPM after inverted (ILM)-flap technique. Case Report One patient with decreased visual acuity (1 LogMar) after unsuccessful inverted ILM-flap technique to treat ODPM, underwent hAM patch implant and was evaluated. A surgical approach including a 2 mm size graft patch of hAM implantation over the optic disc pit followed by fluid–air exchange was performed. A gas endotamponade was finally used. The patient was instructed to maintain face-down position for the first three days after surgery. The hAM patch remained detectable over the pit for the entire 6-months follow-up. The ODPM gradually resolved and visual acuity partially recovered to 0.17 LogMar during follow-up. No postoperative complications or recurrence were reported. Conclusion hAM patch implant may be effective to manage ODPM after unsuccessful inverted ILM-flap.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.