As the myocardium contracts isometrically, it generates vibrations that are transmitted throughout the heart. These vibrations can be measured with an implantable microaccelerometer located inside the tip of an otherwise conventional unipolar pacing lead. These vibrations are, in their audible component, responsible for the first heart sound. The aim of this study was to evaluate, in man, the clinical feasibility and reliability of intracavity sampling of Peak Endocardial Acceleration (PEA) of the first heart sound vibrations using an implantable tip mounted accelerometer. We used a unidirectional accelerometer located inside the stimulating tip of a standard unipolar pacing lead: the sensor has a frequency response of DC to 1 kHz and a sensitivity of 5 mV/G (G = 9.81 m/s-2). The lead was connected to an external signal amplifier with a frequency range of 0.05-1,000 Hz and to a peak-to-peak detector synchronized with the endocardial R wave scanning the isovolumetric contraction phase. Following standard electrophysiological studies, sensor equipped leads were temporarily inserted in the RV of 15 patients (68 +/- 15 years), with normal regional and global ventricular function, to record PEA at rest, during AAI pacing, during VVI pacing, and during dobutamine infusion (up to 20 micrograms/kg per min). PEA at baseline was 1.1 G +/- 0.5 (heart rate = 75 +/- 14 beats/min) and increased to 1.3 G +/- 0.9 (P = NS vs baseline) during AAI pacing (heart rate = 140 beats/min) and to 1.4 G +/- 0.5 (P = NS vs baseline) during VVI pacing (heart rate = 140 beats/min). Dobutamine infusion increased PEA to 3.7 G +/- 1.1 (P < 0.001 vs baseline), with a heart rate of 121 +/- 13 beats/min. In a subset of three patients, simultaneous hemodynamic RV monitoring was performed to obtain RV dP/dtmax, whose changes during dobutamine and pacing were linearly related to changes in PEA (r = 0.9; P < 0.001). In conclusion, the PEA recording can be consistently and safely obtained with an implantable device. Pharmacological inotropic stimulation, but not pacing induced chronotropic stimulation, increases PEA amplitude, in keeping with experimental studies, suggesting that PEA is an index of myocardial contractility. Acute variations in PEA are closely paralleled by changes in RV dP/dtmax, but are mainly determined by LV events. The clinical applicability of the method using RV endocardial leads and an implantable device offers potential for diagnostic applications in the long-term monitoring of myocardial function in man.
The simultaneous recording of PEA I and PEA II with an implantable system offers a new chance to monitor indexes of LV systolic and diastolic function.
AimsCardiac resynchronization therapy (CRT) involves time-consuming procedures to achieve an optimal programming of the system, at implant as well as during follow-up, when remodelling occurs. A device equipped with an implantable sensor able to measure peak endocardial acceleration (PEA) has been recently developed to monitor cardiac function and to guide CRT programming. During scanning of the atrioventricular delay (AVD), PEA reflects both left ventricle (LV) contractility (LV dP/dtmax) and transmitral flow. A new CRT optimization algorithm, based on recording of PEA (PEAarea method) was developed, and compared with measurements of LV dP/dtmax, to identify an optimal CRT configuration.Methods and resultsWe studied 15 patients in New York Heart Association classes II–IV and with a QRS duration >130 ms, who had undergone implantation of a biventricular (BiV) pulse generator connected to a right ventricular (RV) PEA sensor. At a mean of 39 ± 15 days after implantation of the CRT system, the patients underwent cardiac catheterization. During single-chamber LV or during BiV stimulation, with initial RV or LV stimulation, and at settings of interventricular intervals between 0 and 40 ms, the AVD was scanned between 60 and 220 ms, while LV dP/dtmax and PEA were measured. The area of PEA curve (PEAarea method) was estimated as the average of PEA values measured during AVD scanning. A ≥10% increase in LV dP/dtmax was observed in 12 of 15 patients (80%), who were classified as responders to CRT. In nine of 12 responders (75%), the optimal pacing configuration identified by the PEAarea method was associated with the greatest LV dP/dtmax.ConclusionThe concordance of the PEAarea method with measurements of LV dP/dtmax suggests that this new, operator-independent algorithm is a reliable means of CRT optimization.
Cardiac apex rotation, quantified by sophisticated techniques (radiopaque markers and tagged magnetic resonance), has been shown to provide a sensitive index of left ventricle (LV) dynamics. The authors describe the first experimental assessment of cardiac apex rotation using a gyroscopic sensor based on Coriolis force, epicardially glued on the apex. Dynamics of apex rotation were evaluated in a sheep at baseline, after a positive inotropic drug infusion, and after impairment of cardiac function induced by coronary ligation. To evaluate the efficacy of the sensor to monitor cardiac function, results were compared to contractility variations expressed by the maximum value of the first derivative of LV pressure (LVdP/dtMAX). After inotropic drug infusion, a parallel increasing trend resulted for LVdP/dtMAX, for the maximum value of angular velocity measured by the sensor, and for apex rotation angle derived from velocity signal (+146%, +155%, and +11% from baseline, respectively), whereas a decreasing trend of all three parameters resulted after coronary ligation (-35%, -31%, and -65%). The twist pattern also was altered from baseline. These initial results suggest that the use of an implantable rotation sensor based on Coriolis force can be an efficient and effective tool to assess LV torsional deformation both in normal and failing hearts.
The new gyro-based method proved to be a valuable tool to provide dynamic and real-time quantification of eyelid motions. It could be particularly useful for evaluating the effective and natural-like eyeblink restoration provided by ES.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.