Determination of soil particle‐size distribution (PSD) by sieving, hydrometer, and pipette methods as well as by laser diffraction (LD) suffers from inherent flaws, mainly due to the difficulty in defining the size of irregularly shaped particles. Therefore these methods yield only estimates of PSD. The objective of this study was to determine whether a functional relationship exists between the PSDs obtained by the combined sieve‐pipette method and those obtained by LD. Samples from 42 California soils were analyzed. For the LD measurements a Beckman–Coulter LS‐230 apparatus with a 750‐nm laser beam that measures particles in the range of 0.04 to 2000 μm was used, employing the Mie theory for the PSD calculations. Values of 1.5 and 0.2 for the real part and the imaginary term of the refractive index (RI), respectively, gave satisfactory results for the optical model calculations. Volume percentage of the clay‐size fraction obtained by LD was generally lower than mass percentage of the clay fraction derived by the pipette method. The opposite trend was noted for the silt‐size fraction. Coefficients of determination for the regression equations for the clay, silt, and sand fractions determined by the two methods were 0.702, 0.689, and 0.821, respectively. Good agreement between measured and calculated LD values for one size class was accompanied by poor agreement between measured and calculated values for the other. The LD method provides a continuous PSD curve, which enables a detailed data analysis and a flexible application of different particle‐size dependent classification systems.
The commonly used analytic method for assessing total petroleum hydrocarbons (TPH) in soil, EPA method 418.1, is usually based on extraction with 1,1,2-trichlorotrifluoroethane (Freon 113) and FTIR spectroscopy of the extracted solvent. This method is widely used for initial site investigation, due to the relative low price per sample. It is known that the extraction efficiency varies depending on the extracting solvent and other sample properties. This study’s main goal was to evaluate reflectance spectroscopy as a tool for TPH assessment, as compared with three commercial certified laboratories using traditional methods. Large variations were found between the results of the three commercial laboratories, both internally (average deviation up to 20%), and between laboratories (average deviation up to 103%). Reflectance spectroscopy method was found be as good as the commercial laboratories in terms of accuracy and could be a viable field-screening tool that is rapid, environmental friendly, and cost effective.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.