Cognitive reserve (CR) is the phenomenon where older adults with more cognitively stimulating environments show less age-related cognitive decline. The right-lateralized fronto-parietal network has been proposed to significantly contribute to CR and visual attention in ageing. In this study we tested whether plasticity of this network may be harnessed in ageing.We assessed CR and parameters of visual attention capacity in older adults. Transcranial direct current stimulation (tDCS) was employed to increase right fronto-parietal activity during a lateralized whole-report task. At baseline, older adults with greater CR showed a stronger hemifield asymmetry in processing speed towards the left visual-field, indicative of stronger involvement of the right hemisphere in these individuals. Correspondingly, processing speed improved during right prefrontal tDCS. Older adults with lower levels of CR showed tDCS-related improvements in processing speed in the left but not right hemifield: thus tDCS temporarily altered their processing speed asymmetry to resemble that of their high reserve peers.The finding that stronger right hemisphere involvement is related to CR supports Robertson's theory. Furthermore, preserved plasticity within the right prefrontal cortex in older adults suggests this is a viable target area to improve visual processing speed, a hallmark of age-related decline.
Purpose To describe, refine, evaluate, and provide normative control data for two freely available tablet‐based tests of real‐world visual function, using a cohort of young, normally‐sighted adults. Methods Fifty young (18–40 years), normally‐sighted adults completed tablet‐based assessments of (1) face discrimination and (2) visual search. Each test was performed twice, to assess test‐retest repeatability. Post‐hoc analyses were performed to determine the number of trials required to obtain stable estimates of performance. Distributions were fitted to the normative data to determine the 99% population‐boundary for normally sighted observers. Participants were also asked to rate their comprehension of each test. Results Both tests provided stable estimates in around 20 trials (~1–4 min), with only a further reduction of 14%–17% in the 95% Coefficient of Repeatability (CoR95) when an additional 40 trials were included. When using only ~20 trials: median durations for the first run of each test were 191 s (Faces) and 51 s (Search); test‐retest CoR95 were 0.27 d (Faces) and 0.84 s (Search); and normative 99% population‐limits were 3.50 d (Faces) and 3.1 s (Search). No participants exhibited any difficulties completing either test (100% completion rate), and ratings of task‐understanding were high (Faces: 9.6 out of 10; Search: 9.7 out of 10). Conclusions This preliminary assessment indicated that both tablet‐based tests are able to provide simple, quick, and easy‐to‐administer measures of real‐world visual function in normally‐sighted young adults. Further work is required to assess their accuracy and utility in older people and individuals with visual impairment. Potential applications are discussed, including their use in clinic waiting rooms, and as an objective complement to Patient Reported Outcome Measures (PROMs).
To explore the feasibility of using various easy-to-obtain biomarkers to monitor non-compliance (measurement error) during visual field assessments. Methods: Forty-two healthy adults (42 eyes) and seven glaucoma patients (14 eyes) underwent two same-day visual field assessments. An ordinary webcam was used to compute seven potential biomarkers of task compliance, based primarily on eye gaze, head pose, and facial expression. We quantified the association between each biomarker and measurement error, as defined by (1) test-retest differences in overall test scores (mean sensitivity), and (2) failures to respond to visible stimuli on individual trials (stimuli −3 dB or more brighter than threshold). Results: In healthy eyes, three of the seven biomarkers were significantly associated with overall (test-retest) measurement error (P = 0.003-0.007), and at least two others exhibited possible trends (P = 0.052-0.060). The weighted linear sum of all seven biomarkers was associated with overall measurement error, in both healthy eyes (r = 0.51, P < 0.001) and patients (r = 0.65, P < 0.001). Five biomarkers were each associated with failures to respond to visible stimuli on individual trials (all P < 0.001). Conclusions: Inexpensive, autonomous measures of task compliance are associated with measurement error in visual field assessments, in terms of both the overall reliability of a test and failures to respond on particular trials ("lapses"). This could be helpful for identifying low-quality assessments and for improving assessment techniques (e.g., by discounting suspect responses or by automatically triggering comfort breaks or encouragement). Translational Relevance: This study explores a potential way of improving the reliability of visual field assessments, a crucial but notoriously unreliable clinical measure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.