Lung ultrasound (LUS) in the emergency department (ED) has shown a significant role in the diagnostic workup of pulmonary edema, pneumothorax and pleural effusions. The aim of this study is to assess the reliability of LUS for the diagnosis of acute pneumonia compared to chest X-ray (CXR) study. The study was conducted from September 2013 to March 2015. 107 patients were admitted to the ED with a clinical appearance of pneumonia. All the patients underwent a CXR study, read by a radiologist, and an LUS, performed by a trained ED physician on duty. Among the 105 patients, 68 were given a final diagnosis of pneumonia. We found a sensitivity of 0.985 and a specificity of 0.649 for LUS, and a sensitivity of 0.735 and specificity of 0.595 for CXR. The positive predictive value for LUS was 0.838 against 0.7 for CXR. The negative predictive value of LUS was 0.960 versus 0.550 for CXR. This study has shown sensitivity, positive predictive value and negative predictive value of LUS compared to the CXR study for the diagnosis of acute pneumonia. These results suggest the use of bedside thoracic US first-line diagnostic tool in patients with suspected pneumonia.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.