Background Transcatheter closure of perimembraneous ventricular septal defect still poses a challenge due to the adjacent structures of the tricuspid and aortic valves and the risk of atrioventricular block. We report our experience at 2 centers using the KONAR-MF (multifunctional occluder) ventricular septal defect device, which gained its CE mark in May 2018. Methods A retrospective study was carried out on all patients who underwent transcatheter ventricular septal defect closure with the KONAR-MF (multifunctional occluder) ventricular septal defect device at 2 centers. Results A total of 47 patients were identified. The median age and weight of the patients were 25.8 months and 11 kg. The ventricular septal defects that were closed in 5 cases were post-operative hemodynamically significant residual ventricular septal defects. Forty-eight devices were used in the 47 cases. As for the location of the ventricular septal defect, 40/48 (83.33%) ventricular septal defects were perimembranous and 8/48 (16.66%) were muscular. The percutaneous device closure was successful in 46 procedures (95.8%). Device embolization was observed in 2 patients, and a significant residual shunt was observed in 2 cases. In the follow-up, there was no enhancement in the residual shunt in the remaining cases. Temporary atrioventricular block occurred in 2 cases during the procedure and improved after long sheath withdrawal. Conclusion Soft, flexible, and low-profile KONAR-MF (multifunctional occluder) occluders ensure easy and safe implantation, and small sheath sizes allow for their use in small infants. Although near and mid-term follow-ups did not indicate any permanent atrioventricular block, a larger sample of patients and a longer follow-up period is necessary to understand long-term outcomes.
Pulmonary artery pseudoaneurysms are uncommon. They may occur secondary to trauma, infectious diseases, vasculitis syndromes, neoplasms, congenital diseases, and pulmonary hypertension. Due to increasing number of cardiac interventions, iatrogenic complications are among the major causes of pulmonary artery pseudoaneurysms. In this report, we present a 6-month-old patient with pulmonary pseudoaneurysm that occurred following pulmonary balloon angioplasty for the relief of a pulmonary band.
Congenital rupture of tricuspid chordae tendinea leading to severe tricuspid insufficiency is an extremely rare pathology associated with signs and symptoms of congestive heart failure presenting at birth. If the diagnosis and treatment of this pathology are not made early in life fetal demise may become inevitable. We herein present a neonate with central cyanosis and congestive heart failure due to rupture of an anterior leaflet chordae resulting in severe insufficiency of the tricuspid valve who was treated with appropriate surgery.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.