For the analysis of the spectra of complex biofluids, preprocessing methods play a crucial role in rendering the subsequent data analyses more robust and accurate. Normalization is a preprocessing method, which accounts for different dilutions of samples by scaling the spectra to the same virtual overall concentration. In the field of 1H NMR metabonomics integral normalization, which scales spectra to the same total integral, is the de facto standard. In this work, it is shown that integral normalization is a suboptimal method for normalizing spectra from metabonomic studies. Especially strong metabonomic changes, evident as massive amounts of single metabolites in samples, significantly hamper the integral normalization resulting in incorrectly scaled spectra. The probabilistic quotient normalization is introduced in this work. This method is based on the calculation of a most probable dilution factor by looking at the distribution of the quotients of the amplitudes of a test spectrum by those of a reference spectrum. Simulated spectra, spectra of urine samples from a metabonomic study with cyclosporin-A as the active compound, and spectra of more than 4000 samples of control animals demonstrate that the probabilistic quotient normalization is by far more robust and more accurate than the widespread integral normalization and vector length normalization.
Bose-Einstein condensation has been achieved in a magnetic surface microtrap with 4 x 10(5) (87)Rb atoms. The strongly anisotropic trapping potential is generated by a microstructure which consists of microfabricated linear copper conductor of widths ranging from 3 to 30 microm. After loading a high number of atoms from a pulsed thermal source directly into a magneto-optical trap the magnetically stored atoms are transferred into the microtrap by adiabatic transformation of the trapping potential. In the microtrap the atoms are cooled to condensation using forced rf-evaporation. The complete in vacuo trap design is compatible with ultrahigh vacuum below 2 x 10(-11) mbar.
Metabonomic analysis of biofluids and tissues utilizing high-resolution NMR spectroscopy and chemometric techniques has proven valuable in characterizing the biochemical response to toxicity for many xenobiotics. To assess the analytical reproducibility of metabonomic protocols, sample preparation and NMR data acquisition were performed at two sites (one using a 500 MHz and the other using a 600 MHz system) using two identical (split) sets of urine samples from an 8-day acute study of hydrazine toxicity in the rat. Despite the difference in spectrometer operating frequency, both datasets were extremely similar when analyzed using principal components analysis (PCA) and gave near-identical descriptions of the metabolic responses to hydrazine treatment. The main consistent difference between the datasets was related to the efficiency of water resonance suppression in the spectra. In a 4-PC model of both datasets combined, describing all systematic dose- and time-related variation (88% of the total variation), differences between the two datasets accounted for only 3% of the total modeled variance compared to ca. 15% for normal physiological (pre-dose) variation. Furthermore, <3% of spectra displayed distinct inter-site differences, and these were clearly identified as outliers in their respective dose-group PCA models. No samples produced clear outliers in both datasets, suggesting that the outliers observed did not reflect an unusual sample composition, but rather sporadic differences in sample preparation leading to, for example, very dilute samples. Estimations of the relative concentrations of citrate, hippurate, and taurine were in >95% correlation (r(2)) between sites, with an analytical error comparable to normal physiological variation in concentration (4-8%). The excellent analytical reproducibility and robustness of metabonomic techniques demonstrated here are highly competitive compared to the best proteomic analyses and are in significant contrast to genomic microarray platforms, both of which are complementary techniques for predictive and mechanistic toxicology. These results have implications for the quantitative interpretation of metabonomic data, and the establishment of quality control criteria for both regulatory agencies and for integrating data obtained at different sites.
A new triple-resonance (TXI) (1H, 13C, 15N) high-resolution nuclear magnetic resonance (NMR) capillary probe with 2.5-microL NMR-active sample volume (V(obs)) was built and tested for applications with mass- and volume-limited samples and for coupling of microbore liquid chromatography to NMR. This is the first microliter probe with optimized coil geometry for use with individual capillary tubes with an outer diameter of 1 mm. The 90 degree pulse lengths of the 1-mm microliter probe were below 2 micros for proton, below 8 micros for carbon, and below 20 micros for nitrogen, and a spectral line width at signal half-height below 1 Hz was obtained. Compared to a conventional 5-mm probe, the new 600-MHz 1-mm TXI microliter probe with z-gradient shows an increase in mass sensitivity by a factor of 5, corresponding to a 25-fold reduction in measuring time. The consumption of costly deuterated solvent is reduced by at least 2 orders of magnitude. The 1-mm TXI microliter probe with z-gradient allows the measurement of one-dimensional 1H NMR and two-dimensional heteronuclear NMR spectra with a few nanomoles (micrograms) of compound with high sensitivity, speed, and quality. This is a breakthrough for discrete sample NMR spectroscopy with paramount importance for structure elucidation in natural compound chemistry and metabolic research. It offers also advantages for linking chromatographic methods to NMR in a nindustrial environment. Capillary tube NMR may find new applications in areas where high sample throughput is essential, e.g., in the quality control of large sample arrays from parallel chemistry, screening, and compound depositories. It has the potential to increase the sample throughput by 1 order of magnitude or more if new hardware for fast sample handling and exchange becomes available.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.