The present investigation was undertaken to examine whether maximal oxygen uptake (VO2max) and anaerobic threshold (AT) measured during incremental treadmill exercise would be affected by the exercise protocol in trained and untrained individuals. Fifteen untrained men, 10 untrained women, and 12 trained individuals participated in this study. The Astrand, Bruce, and Costill/Fox protocols were selected for comparison. Each subject was tested using all three protocols and the three tests were conducted in a randomized counterbalanced order. During each test, oxygen uptake was measured every 30 s and the test was terminated according to the standard criteria. The VO2max was determined by averaging the two consecutive highest measurements, whereas AT was determined using ventilatory parameters following the V-slope technique. The Astrand, Bruce, and Costill/Fox protocols produced test durations of 9.8 (SEM 0.5), 12.4 (SEM 0.4), and 4.9 (SEM 0.3) min, respectively, in the untrained men, 9.0 (SEM 0.8), 11.0 (SEM 0.6), and 5.3 (SEM 0.6) min, respectively, in the untrained women, and 14.5 (SEM 0.5), 17.0 (SEM 0.5) and 10.4 (SEM 0.4) min, respectively, in the trained men. In the untrained men and women, no differences in VO2max were observed among the three different protocols, but AT was lower when using the Bruce compared to the Astrand protocol. In the trained men, VO2max and AT were lower when using the Bruce protocol than either the Astrand or Costill/Fox protocols. In conclusion, VO2max measured during treadmill exercise is not affected by the protocol of the test and using a running protocol of short duration (i.e. about 5 min) could be a time-efficient way of assessing VO2max in healthy untrained subjects. In trained subjects, however, a protocol consisting of running with small increments in gradient is effective in eliciting a higher VO2max. The lower AT associated with the Bruce protocol seen in both untrained and trained groups suggests this aerobic parameter is protocol dependent and this protocol dependency is not affected by training status.
To examine whether the validity of perception-based intensity regulation would be affected by exercise duration, 20 subjects were recruited to complete a maximal exercise test (GXT) and four submaximal trials of varying duration and intensity using a cyle ergometer. During GXT, ratings of perceived exertion (RPE), oxygen uptake VO2, heart rate (HR), and power output (PO) equivalent to 50 and 75% VO2peak were determined. During each trial, subjects were to produce and maintain a workload using RPE estimated at 50 or 75% VO2peak for 20 or 40 min, and VO2, HR, and PO were measured throughout the exercise. No differences in average VO(2) were found between the estimation and production trial of either duration. However, average HR and PO were lower (P < 0.05) during the production trial of both durations. It appears that exercise duration has a minimal impact upon the accuracy of using RPE to regulate a target metabolic demand.
Anaerobic exercise is involved in many recreational and competitive sport activities. This study first established regression equations to predict maximal anaerobic power and then cross-validated these prediction equations. Using stepwise multiple regression analysis prediction equations for relative (watts per kilogram of body mass) and absolute (watts) mean and peak anaerobic power using the 30-second Wingate Test as the power measure were determined for 40 boys (age, 11-13 years). Percentage of body fat, free-fat weight, midthigh circumference, and 30-m dash were the independent predictive variables with the generated regression equations subsequently cross-validated using 20 different boys (age, 11-13 years). Significant correlations (Pearson r) were found for the cross-validation subjects between the measured power outputs and predicted power outputs for relative mean power (r = 0.48, p < 0.05), absolute mean power (r = 0.77, p < 0.01), and absolute peak power (r = 0.76, p < 0.01). Using paired t-tests, no significant mean differences (p > 0.05) were found for the same subjects between actual and predicted power outputs for relative mean power, absolute mean power, and absolute peak power. Prediction of maximal anaerobic power from selected anthropometric measurements and 30-m dash appears tenable in 11-13-year-old boys and can be accomplished in a simple cost- and time-effective manner.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.