The results of an absolute silicon molar mass determination of two independent sets of samples from the highly 28Si-enriched crystal (AVO28) produced by the International Avogadro Coordination are presented and compared with results published by the Physikalisch-Technische Bundesanstalt (PTB, Germany), the National Research Council (NRC, Canada) and the National Metrology Institute of Japan (NMIJ, Japan). This study developed and describes significant changes to the published protocols for producing absolute silicon isotope ratios. The measurements were made at very high resolution on a multi-collector inductively coupled plasma mass spectrometer using tetramethylammonium hydroxide (TMAH) to dissolve and dilute all samples. The various changes in the measurement protocol and the use of TMAH resulted in significant improvements to the silicon isotope ratio precision over previously reported measurements and in particular, the robustness of the 29Si/30Si ratio of the AVO28 material. These new results suggest that a limited isotopic variability is present in the AVO28 material. The presence of this variability is at present singular and therefore its significance is not well understood. Fortunately, its magnitude is small enough so as to have an insignificant effect on the overall uncertainty of an Avogadro constant derived from the average molar mass of all four AVO28 silicon samples measured in this study. The NIST results confirm the AVO28 molar mass values reported by PTB and NMIJ and confirm that the virtual element–isotope dilution mass spectrometry approach to calibrated absolute isotope ratio measurements developed by PTB is capable of very high precision as well as accuracy. The Avogadro constant NA and derived Planck constant h based on these measurements, together with their associated standard uncertainties, are 6.02214076(19) × 1023 mol−1 and 6.62607017(21) × 10−34 Js, respectively.
A solution-based inductively coupled plasma optical emission spectrometric (ICP-OES) method is described for elemental analysis with relative expanded uncertainties on the order of 0.1% relative. The single-element determinations of 64 different elements are presented, with aggregate performance results for the method and parameters for the determination of each element. The performance observed is superior to that previously reported for ICP-OES, resulting from a suite of technical strategies that exploit the strengths of contemporary spectrometers, address measurement and sample handling noise sources, and permit rugged operation with small uncertainty. Taken together, these strategies constitute high-performance ICP-OES.
A procedure is introduced that can mitigate the deleterious effect of low-frequency noise [Formula: see text] often termed drift [Formula: see text] on the precision of an analytical experiment. This procedure offers several performance benefits over traditional designs based on the periodic measurement of standards to diagnose and correct for variation in instrument response. Using repeated measurements of every sample as a drift diagnostic, as opposed to requiring the periodic measurement of any given sample or standard, the analyst can better budget the measurement time to be devoted to each sample, distributing it to optimize the uncertainty of the analytical result. The drift is diagnosed from the repeated measurements, a model of the instrument response drift is constructed, and the data are corrected to a "drift-free" condition. This drift-free condition allows data to be accumulated over long periods of time with little or no loss in precision due to drift. More than 10-fold precision enhancements of analytical atomic emission results have been observed, with no statistically significant effects on the means. The procedure is described, performance data are presented, and matters regarding the procedure are discussed.
A new variety of analytical atomic flame spectrometry called laser enhanced ionization (LEI) has been developed. The method relies on the enhanced rate of thermal ionization of the analyte element following photoexcitation with a dye laser tuned to an appropriate transition wavelength. This enhanced Ionization rate can be electrically measured directly in the flame, and therefore no optical detection system is required.Detection limits have been measured for 18 elements, showing
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.