According to the data of the Statistic Poland, noise is the most common harmful factor in the work environment in Poland. In 2020, the number of persons exposed to noise was 181.7 thousand person. Reducing the noise hazard is a primary objective of vibro-acoustic research, and modern technology allows to achieve this goal in numerous ways. The most important and widespread technique used to reduce the risk of noise exposure of workers is to place noise absorbing or reflecting elements in the workplace. One of the less conventional methods used to produce such elements is the use of Fused Deposition Modelling. The opportunities that this method presents allow for manufacturing of noise barriers with advanced internal structures, which can reduce the noise transmission or manipulate the propagation of the sound wave. This article describes the study of acoustic properties of a noise barrier made using a 3D printer. The influence of various 3D printing settings on the obtained acoustic properties of the barrier was investigated. By measuring the acoustic pressure level and the particle velocity in three directions, the acoustic properties of the created barrier were determined.
Hałas na stanowiskach pracy wciąż jest głównym zagrożeniem dla pracowników zakładów przemysłowych. Zastosowanie obudów i barier dźwiękoizolacyjnych w celu ograniczania tego zagrożenia nie zawsze jest możliwe lub wystarczające. Stosunkowo nowym i obiecującym sposobem redukcji hałasu jest wykorzystanie metamateriałów akustycznych, które przekierowują bądź pochłaniają falę dźwiękową, a najwyższą skuteczność wykazują przy częstotliwości bliskiej częstotliwości rezonansowej. Metamateriały akustyczne służą przede wszystkim do redukcji hałasu wąskopasmowego. W artykule przedstawiono ich modele numeryczne, które posłużyły do wyznaczenia częstotliwości rezonansowych. Symulacje przeprowadzono w dwóch różnych programach przeznaczonych do analizy metodą elementów skończonych (MES). Otrzymane wyniki wskazują, że metamateriał o strukturze tunelowej z umieszczonymi wewnątrz rezonatorami Helmholtza może redukować hałas w kilku pasmach częstotliwości (w zakresie średnio- i wysokoczęstotliwościowym) oraz w większym stopniu niż metamateriał o strukturze tunelowej bez rezonatorów.
Visualization of the parameters of acoustic field is a relatively new research technique that allows for illustrate the parameters characterizing the acoustic field for specific points of space near the machine. Images obtained in this way have many applications in the analysis of prototype devices, construction, as well as in the analysis of the acoustic field around industrial machines. The article presents the principles of operation of the mobile experimental setup. The results of studies of noise emission on the example of loudspeaker set and vacuum pump are also discussed.
Passive noise reduction means are commonly used to reduce noise in the industry but, unfortunately, their effectiveness is poor in the low frequency range. By applying active structural acoustic control to the enclosure walls significant improvement of the insulating properties in this frequency range can be achieved. In this paper a model of double panel structure with ASAC is presented. The structure consists of two aluminium plates separated by an air gap. Two inertial magnetoelectric actuators and two piezoceramic MFC sensors were used for controlling the structure. A multichannel FxLMS algorithm with virtual error microphone technique is used as a control algorithm. The signal of a virtual error microphone is extrapolated basing on signals from MFC sensors. Performance of this actively controlled structure for tonal signals at selected frequencies is presented in the article. During the study, a double panel structure was mounted on one wall of sound insulating enclosure located in an acoustic chamber. During the measurements local and global reduction of noise test signal was investigated.
Wstęp: Sprawność poznawcza jest kluczowa dla wielu obszarów działania człowieka. Wpływa na efektywność pracowników i bezpieczeństwo pracy. Ważnym elementem profilaktyki wypadków przy pracy jest odpowiedni dobór zawodowy, który polega na sprawdzeniu cech kandydatów na dane stanowisko pracy, i w tym celu przeprowadza się diagnozę psychologiczną. Celem badania było opracowanie narzędzi do diagnozy poznawczej, które cechują się dobrymi własnościami psychometrycznymi. Materiał i metody: Opracowano narzędzia do diagnozy czasu reakcji prostej (Abili-time), czasu reakcji z wyborem (Abili-select), przedłużonej koncentracji (Abili-space, Abili-digit) i pamięci roboczej (Abili-langmem, Abili-mathmem). Przeprowadzono badania walidacyjne z udziałem 221 osób w wieku 20-60 lat w celu oceny trafności i rzetelności (spójność wewnętrzna i stabilność czasowa) oraz z udziałem 61 osób w badaniu retest po 3 mies. od I pomiaru. Do oceny trafności zastosowano testy papierowe (CTT, TUS, Powtarzanie cyfr z WAIS-R(PL)) oraz pochodzące z Wiedeńskiego systemu testów (RT, SIGNAL, CORSI, ALS). Wyniki: Analiza wykazała, że testy Abili-time i Abili-select charakteryzują się zadowalającą spójnością wewnętrzną. Analiza stabilności czasowej wykazała istotne korelacje test-retest w przypadku Abili-select, Abili-space, Abili-digit i Abili-langmem. Nieco niższą stabilnością czasową cechuje się Abili-time. Nie potwierdzono stabilności czasowej Abili-mathmem. Uzyskano istotne korelacje między wynikami opracowanych narzędzi z miarami mierzącymi podobne konstrukty. Wnioski: Przeprowadzone badania potwierdzają trafność i rzetelność Abili-time, Abili-select i Abili-space. Dalszych prac wymagają testy do badania pamięci roboczej, które są warte uwagi z powodu braku dostępnych na rynku innych narzędzi do badania tych funkcji. Dalsze badania powinny obejmować większą liczbę osób, jak również przeprowadzenie prac normalizacyjnych. Med. Pr. 2023;74(2):103-118
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.