The biological potency of botulinum toxin type A (BoNTA) in biotechnology-derived products was assessed by the mouse LD50 bioassay (MBA) and the T47D cell culture assay.
Reversed-phase liquid chromatography (RP-LC) and size exclusion liquid chromatography (SE-LC) methods were validated for the assessment of recombinant human parathyroid hormone (rhPTH 1-34). The gradient RP-LC method was carried out on a Zorbax 300 SB C(18) column (150 mm × 4.6 mm i.d.), maintained at 40 °C. The mobile phase A consisted of 0.1 M sodium sulphate buffer, pH 2.3, and the mobile phase B was acetonitrile. The SE-LC method was carried out on a BioSep-SEC-S 2000 column (300 mm × 7.8 mm i.d.), maintained at 25 °C. The mobile phase consisted of 0.1 M phosphoric acid buffer, pH 2.5, run isocratically at a flow rate of 0.7 mL min(-1). Chromatographic separation was obtained with retention times of 12.2 min, and 13.2 min, and was linear over the concentration range of 1-250 μg mL(-1) (r(2) = 0.9997) and 2-300 μg mL(-1) (r(2) = 0.9993), respectively, for RP-LC and SE-LC, with photodiode array (PDA) detection at 214 nm. Specificity was established in degradation studies, which also showed that there was no interference of the excipients. Equally, the accuracy was 100.49% and 100.22%, with bias lower than 1.12% and 0.81% respectively. Moreover, the in vitro cytotoxicity test of related proteins and higher molecular weight forms showed significant differences (p < 0.05). Chromatographic methods were applied for the content/potency assessment of rhPTH and related proteins in biopharmaceutical injectable dosage forms, and the results were correlated with those of in vitro and in vivo bioassays. It is concluded that the employment of the methods in conjunction allows a great improvement in monitoring stability, contributing to evaluate alternatives which improve the quality control and thereby assure the therapeutic efficacy of the biotechnology-derived medicine.
Recombinant human erythropoietin is a sialoglycoprotein that stimulates erythropoiesis. To assess potency of human erythropoietin produced by recombinant technology, we investigated an in vitro TF-1 cell proliferation assay, which was applied in conjunction with a reversed-phase liquid chromatography method for the determination of the content of sialic acids. The results obtained, which were higher than 126.8ng/μg, were compared with those obtained with the in vivo normocythaemic mouse bioassay. The in vitro assay resulted in a non-significant lower mean difference of the estimated potencies (0.61% ± 0.026, p > 0.05). The use of this combination of methods represents an advance toward the establishment of alternative in vitro approaches, in the context of the Three Rs, for the potency assessment of biotechnology-derived medicines.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.