An increased trochlear sulcus angle/trochlear depth ratio is a significant predictor of chondromalacia patella. Medial meniscus injury is more prevalent in patients with chondromalacia patella in association with impairment in knee biomechanics and the degenerative process.
Purpose. Surgical procedures are likely to be stressful for patients and their families. Total knee arthroplasty (TKA) is a major surgical procedure used in the treatment of osteoarthritis. During this procedure the sounds of the saw and hammer may irritate the patient and adversely affect mood. The present study examines the effect of these intraoperative sounds during TKA on postoperative mood and anxiety, by comparing two different anesthetic procedures.
Methods. A total of 40 patients who underwent TKA for grade IV gonarthrosis participated in the study. Patients were randomly divided into two groups: 20 patients in the general anesthesia group and 20 patients in the spinal anesthesia group. Mood and anxiety changes were evaluated using the Profile of Mood States (POMS) and State-Trait Anxiety Inventory (STAI) instruments, respectively. Results. The postoperative POMS value in the spinal anesthesia group was definitively higher than the general anesthesia group, though the difference in preoperative and postoperative POMS and STAI scores between the two groups was not significant. Conclusion. It would seem that sounds of hammer and saw have no evident negative effect on patient's mood. Regional anesthesia is advisable for TKA patients and appropriate sedation can be administered during the operation if needed.
BackgroundThe aim of the present study was to investigate the safety of bioabsorbable plates and screws in humans.MethodsFor this purpose, an implant system based on [poly(lactic-co-glycolic acids)(85:15)] was designed. The system was tested for pH, temperature, and swelling and then its surface morphology was analyzed for surface porosity using environmental electron microscopy. Then, the effects of this bioabsorbable system on the viability and profileration of osteocytes were examined on a molecular level via in vitro experiments. A [poly(lactic-co-glycolic acids)(90:10)] bioabsorbable implant, which is commercially available and used in orthopedic surgery, was used as control group. For the statistical evaluation of the data obtained in the present study, the groups were compared by Tukey HSD test following ANOVA. The significance level was set as p < 0.05.ResultsIt was observed that the osteocytes cultivated on the PLGA system designed in the present study included more live cells and allowed more proliferation compared to the control.ConclusionOne of the criteria in the selection of implants for orthopedic surgery is that a good implant should not need removal and thus a second surgery. In the present study, a bioabsorbable implant was designed considering this criterion. The present study is the first step to prove the safety of this new design by in vitro toxicity and viability experiments.
Although improvements have occurred in the access to and utilisation of healthcare services, consultation by patients of bone setters seems to be a sociocultural and educational issue rather than a problem of lack of medical insurance.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.