An enzyme-linked immunosorbent assay (ELISA) was adapted for the serological differential diagnosis of cystic or alveolar echinococcosis in man caused by Echinococcus granulosus or E. multilocularis respectively. By affinity chromatography using rabbit anti hydatid fluid IgG coupled covalently to CNBr-Sepharose 4B a protein fraction (Em 1) containing shared antigens of both parasites could be isolated from an extract of E. multilocularis metacestode tissue. From the same source another antigen fraction (Em 2) with a high degree of specificity for E. multilocularis was prepared by immunosorption. Antigen Em 1 was equally sensitive for the detection of antibodies against E. granulosus and E. multilocularis, whereas antigen fraction Em 2 appeared to be more specific for E. multilocularis. A correct serological differential diagnosis was achieved in 95% of 57 confirmed cases of human cystic or alveolar echinococcosis by the simultaneous use of both antigen fractions in the ELISA and by comparison of their reactivities.
We compared four versions of the enzyme-linked immunosorbent assay for their suitability for detecting staphylococcal enterotoxins. The sandwich with labeled antibody proved to be the best. We used it with a sorbent consisting of antibody-coated polystyrene spheres reacted with 20 ml of food extract. The sensitivity of the test was 0.1 ng of enterotoxin per ml, which is far below clinical relevance. The succinimidyl-pyridyl-dithio-propionate enzyme coupling method of Pharmacia was superior to the two-step glutaraldehyde technique. Interfering protein A was eliminated by the simple addition of normal rabbit serum to the extracts. A diagnostic kit is now available.
Abstract. Pregnant cows can be successfully immunized with different proteins and subsequently deliver large volumes of potent antisera in their colostrum. An anti‐human immunoglobulin has been prepared in this way which is excellently suited for the demonstration of incomplete blood group antibodies of the IgG class. At a dilution of 1:50 it was equivalent to a commercial antiglobulin serum of high quality. Anti‐complementary antibodies were also present but at a considerably lower concentration than the antibodies against IgC.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.