The conduction cooled high-temperature superconductor (HTS) SMES (superconducting magnetic energy storage) was operated in cryogenic temperature and high vacuum conditions. Thus, the insulation design at the conditions is an important element that should be established to accomplish compact design is a big advantage of HTS SMES. However, the behaviors of insulators for the conditions are virtually unknown. Therefore, we need to researches and development of insulation concerning application of the conduction cooled HTS SMES. In this study, we experimented on insulation characteristics of SMES system. Also, we investigated about insulation characteristics of suitable materials to insulator for conduction cooled HTS SMES. As these results, we had basic data for insulation materials selection and insulation design of cryocooler-to-magnet coil for the development of 600 kJ class conduction cooled HTS SMES.Index Terms-Electric breakdown, flashover, HTS SMES, vacuum insulation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.