Capillary adhesive bonding is used successfully to integrate microsystems. To ensure high reliability and quality of the interconnection technique, it is imperative that the propagation of adhesives in the joints be controlled. Two adhesives frequently used in capillary adhesive bonding were examined: a one-component, UV-curing methacrylate adhesive (Dymax 191-M), and a two-component epoxy resin bonding adhesive curing at room temperature (Epo-tek 302-3M). The propagation of these adhesives in joints with different gap heights of 2-20 m between two PMMA surfaces and between one PMMA and one PI surface was measured and compared with the theoretical adhesive propagation in accordance with the Hagen-Poiseuille equation for a gap flow, with the capillary pressure taken into account.Once the dynamic viscosity, the wetting angle and the surface tension of the adhesive have been determined as a function of the measuring time, the measured propagation of the Epo-tek 302-3M and Dymax 191-M adhesives can be described in good agreement with the theory for all the gap heights under study.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.