All surgical operations have the potential for contamination, and the equipment used can harbour bacteria. We collected samples from 100 elective primary hip and knee arthroplasties. These showed rates of contamination of 11.4% for the sucker tips, 14.5% for light handles, 9.4% for skin blades and 3.2% for the inside blades used during surgery; 28.7% of gloves used for preparation were also contaminated. Of the samples taken from the collection bags used during hip arthroplasty, 20% grew bacteria, which represents a significant microbial reservoir. Also, 17% of theatre gowns were contaminated at the end of the operation. Contamination was found in 10% of the needles used during closure of the fascia. Overall, 76% of the organisms grown were coagulase-negative staphylococcus. A total of 63% of operations showed contamination in the field of operation. Some changes in practice are suggested. Follow-up for a minimum of two years revealed one deep infection but the organism was not identified as a contaminant. These data provide a baseline for studying the bacteriology of the surgery of revision arthroplasty.
A ll surgical operations have the potential for contamination, and the equipment used can harbour bacteria. We collected samples from 100 elective primary hip and knee arthroplasties. These showed rates of contamination of 11.4% for the sucker tips, 14.5% for light handles, 9.4% for skin blades and 3.2% for the inside blades used during surgery; 28.7% of gloves used for preparation were also contaminated. Of the samples taken from the collection bags used during hip arthroplasty, 20% grew bacteria, which represents a significant microbial reservoir. Also, 17% of theatre gowns were contaminated at the end of the operation. Contamination was found in 10% of the needles used during closure of the fascia. Overall, 76% of the organisms grown were coagulase-negative staphylococcus. A total of 63% of operations showed contamination in the field of operation. Some changes in practice are suggested. Follow-up for a minimum of two years revealed one deep infection but the organism was not identified as a contaminant. These data provide a baseline for studying the bacteriology of the surgery of revision arthroplasty. [Br] 1999;81-B:886-9.
J Bone Joint Surg
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.