For the first time, ion mobility spectrometers (IMS) with radioactive and UV ionization sources in combination with multicapillary columns (MCCs) have been used to determine methyl tert-butyl ether (MTBE), a gasoline additive, in water and nitrogen as well as the monoaromatic compounds benzene, toluene, and m-xylene (BTX). A membrane extraction unit was set up to extract the substances from water, which is simple, effective, and easy to automate for further applications. Thus, the detection of MTBE and BTX of gasoline vapors was accomplished after a preliminary silicone membrane extraction. Two-dimensional data analyses of IMS-chromatograms allow us to separate these substances clearly according to their different retention and drift times. Method detection limits for MTBE were 2 microg/L (UV) and 30 pg/L (63Ni) in nitrogen and 20 mg/L (UV) and 1 microg/L (63Ni) in water. Rather a good reproducibility was achieved with relative standard deviations of between 2.9 and 9%. The method presented in this article has been proven to be suitable for nearly real-time monitoring as the total analysis time is less than 90 s. As an example of application, the detection of MTBE and BTX in a mixture of volatile organic compounds of pure gasoline using the 2-D IMS-chromatogram is presented.
Eight vegetative bacterial strains and two spores were characterized by pyrolysis-gas chromatography with differential mobility spectrometry (py-GC/DMS) yielding topographic plots of ion intensity, retention time, and compensation voltage simultaneously for ions in positive and negative polarity. Biomarkers were found in the pyrolysate at characteristic retention times and compensation voltages and were confirmed by standard addition with GC/MS analyses providing discrimination between Gram negative and Gram positive bacterial types, but no recognition of individual strains within the Gram negative bacteria. Principal component analysis was applied using two dimensional data sets of ion intensity versus retention time at five compensation voltages including the reactant ion peaks all in positive and negative ion polarity. Clustering was observed with compensation voltage (CV) chromatograms associated with ion separation in the DMS detector and little or no clustering was observed with the reactant ion peaks or CV chromatograms where ion separation is poor. Consistent clustering of Gram positive B. odysseyi and Gram negative E. coli in both positive and negative polarities with the reactant ion peak chromatograms and key CV chromatograms suggests common but unknown common chemical compositions in the pyrolysate.
A microfabricated drift tube for differential mobility spectrometry (DMS) was used with pyrolysis-gas chromatography (py-GC) to chemically characterize bacteria through three-dimensional plots of ion intensity, compensation voltage from differential mobility spectra, and chromatographic retention time. The DMS analyzer provided chemical information for positive and negative ions simultaneously from chemical reactions between pyrolysis products in the GC effluent and reactant ions of H+(H2O)n and O2-(H2O)n in air at ambient pressure. Authentic standards for chemicals formed in the pyrolysis of bacteria showed favorable matches with plots from py-GC/DMS analysis and were supported by py-GC/MS results. These and other yet-unidentified constituents provided a means to distinguish Escherichia coli from Micrococcus luteus. A Gram-positive spore former (Bacillus megaterium) was distinguished by an abundant peak for crotonic acid evident in positive and negative ions and not observed with M. luteus. In contrast, plots from py-GC/DMS of lipid A and lipoteichoic acid showed poor matches to plots for a Gram-negative (E. coli) bacterium and a Gram-positive (M. luteus) bacterium and the differences were attributed to differences in genus sources of the biopolymers. A significant percentage of the chemical information available in py-GC/DMS is unidentified, and the analytical utility must be established. Precision in the chemical measurement was determined as +/- 0.2 V, 10% relative standard deviation (RSD), and +/- 0.05 min for compensation voltage, peak intensity, and retention time, respectively. The minimum number of total bacteria (cell forming units) detected was 6000 though detection limits and resolution could be varied by the magnitude of the separation voltage in the differential mobility spectrometer.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.