Provided that the working environment is not bright, the results suggest that low-cost RD can be used for the recognition of low-contrast details in radiographies of the chest. Further studies including more display models are necessary. Among different ambient lighting and luminance settings, these studies should include a closer analysis of the special features of digital systems such as brightness/contrast adaptation, picture enlargement (zoom shot), and image inversion.
Restenosis after PTCA is still an unresolved problem and occurs in approximately 30% of our patients despite a stent implantation rate of up to 63%. Intracoronary brachytherapy has the potential to counteract the proliferative component of restenosis as well as to prevent shrinking of the coronary artery. Two years ago, we applied for the license to use the Novoste Beta-Cath system. This is the first report of its use in Germany. Attaining the license was complicated by the facts that this device did not yet have CE-certification (MPG section 17), that brachytherapy is not yet an approved method of treatment (StrSchV section 41), the report of the BfS and the approval by an accredited ethical committee. The application becomes even more complicated by the amount demanded by the LfU for insurance: 1 Million DM for each individual patient (AtDeckV section 15). The final local inspection needs to be performed by an expert from the LfAS (StrSchV section 76). Strontium-90 decays into Yttrium-90 with a half-life time of approximately 28 years. Yttrium-90, too, is a pure beta-emitter with a shorter half-life time of approximately 64 hours and a considerably higher electron energy of maximum 2.27 MeV. Yttrium-90 is the therapeutic agent. The radiation source of the Beta-Cath system consists of 12 single, separate cylinders (pellets, seeds) with a total length of 3 cm. The activity of the total train is approximately 1.3 to 1.5 GBq (35 to 40 mCi). For verification of the dose rate provided by the manufacturer, we performed a check using the GafChromic film. The test dose (exactly 2 mm from the center of the long axis of the activity train) was 150 Gy. We obtained the following results for the optical density: reference source: 0.29 +/- 0.01, source C: 0.318 +/- 0.013 and source D: 0.317 +/- 0.028. For a dose rate of e.g. 0.083 Gy/s, the radiation times are 169 s for a dose of 14 Gy (vessel diameter 2.7 to 3.35 mm) or 217 s for 18 Gy (vessel diameter 3.36 to 4.0 mm), respectively. In our cath lab, the following dose rates were measured: at the lead container: 20 microSv/h, surface of the transfer device: 400 microSv/h, surface of the phantom: 20 microSv/h and surface of the bail out box: 100 microSv/h. Because moving the source train to the tip of the catheter takes only approximately 1 s, the exposure to other tissues or organs is negligible. However, inappropriate handling of the device could cause significant radiation of other organs. Therefore, the importance of intensive training cannot be overemphasized. The results of the currently ongoing multicenter trials (Beta-Cath system trial in the USA and the BRIE trial in Europe) are being anxiously awaited and will have a decisive impact on the medical acceptance of intracoronary radiation for prophylaxis and/or therapy of restenosis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.