We report a miniaturized fiber inline Fabry-Perot interferometer (FPI), with an open micro-notch cavity fabricated by one-step fs laser micromachining, for highly sensitive refractive index measurement. The device was tested for measurement of the refractive indices of various liquids including isopropanol, acetone and methanol at room temperature, as well as the temperature-dependent refractive index of deionized water from 3 to 90 degrees C. The sensitivity for measurement of refractive index change of water was 1163 nm/RIU at the wavelength of 1550 nm. The temperature cross-sensitivity of the device was about 1.1x10(-6) RIU/degrees C. The small size, all-fiber structure, small temperature dependence, linear response and high sensitivity, make the device attractive for chemical and biological sensing.
Breathlessness induced by hypercapnia may be related to the sensation of respiratory effort or to the central or peripheral effects of CO2 , To examine the relationship among breathlessness, respiratory effort, and hypercapnia, we studied eight normal naive subjects. By using a visual feedback system, subjects maintained a constant ventilation of 50-60 Umin. PETC0 2 was held at 40 mm Hg during the first 2 min of each trial (control period), then for 4 min (test period) was either kept at 40 mm Hg or elevated to 50 mm Hg. At the end of each control and test period, subjects were asked to give separate ratings for dyspnea (an unpleasant urge to breathe) and for the sense of respiratory effort (analogous to lifting a weight) on a 50-cm visual analog scale. Hypercapnia was associated with a significant reduction In effort ratings (-7.3 ± 6.4, mean ± SO, P < 0.05) and a concomitant Increase In dyspnea (+6.6 ± 6.0, P< 0.05). Weconclude that dyspnea associated with hypercapnia Is dissociated from changes In respiratory effort, and that CO 2 has a direct central effect that leads to breathlessness. Our data also suggest that the sense of effort at a given level of ventilation Is less when the ventilation is the result of "reflex" stimuli to breathe rather than "voluntary" signals to the respiratory muscles.
We report a miniaturized inline Fabry-Perot interferometer directly fabricated on a single-mode optical fiber with a femtosecond laser. The device had a loss of 16 dB and an interference visibility exceeding 14 dB. The device was tested and survived in high temperatures up to 1100 degrees C. With an accessible cavity and all-glass structure, the new device is attractive for sensing applications in high-temperature harsh environments.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.