ABSTRACT.Purpose: To determine whether anthropomorphic measurements are associated with ocular and general parameters. Methods: The population-based Beijing Eye Study, which included 4439 participants (age > 40 years) out of 5324 individuals invited to be examined in 2001, was repeated in 2006 with 3251 (73.2% of 4439, or 61.1% of 5324) participants. The anthropomorphic measurements body height and weight, socioeconomic variables and ocular parameters were evaluated. Results: Of the 3251 individuals included in the study, measurements of body height and weight were available for 3214 (98.9%) participants. In multivariate analysis, body height was significantly associated with the systemic parameters higher level of education (p = 0.004), higher income (p < 0.001), lower body mass index (p < 0.001), lower systolic blood pressure (p = 0.012), higher diastolic blood pressure (p < 0.001), male gender (p < 0.001), lower age (p < 0.001) and living in an urban region (p < 0.001), and with the ocular parameter of a deep anterior chamber (p < 0.001). The association between marked hyperopia and low body height was statistically marginal (p = 0.11). Conclusion: In adult Chinese, body height is associated with higher level of education, higher income, lower systolic blood pressure, higher diastolic blood pressure and lower body mass index, in addition to living in an urban region and being male. From an ophthalmic point of view, tall individuals had deeper anterior chambers. There was a tendency towards lower body height and marked hyperopia. Because the socioeconomic, systemic and ocular parameters examined influence the occurrence and therapy of ocular diseases, these data may be helpful in the assessment of risk factors and in the diagnosis and treatment of ocular diseases.
Anterior segment OCT measurements show significant differences between eyes with APAC, contralateral eyes at risk for APAC, and normal eyes. This may open possibilities for a semi-automatic assessment of subjects at risk for APAC by anterior segment OCT. The anterior chamber angle was closed most often in the nasal quadrant, and, in APAC, the angle was closed in three or more quadrants.
PurposeTo describe the cumulative 5 year incidence of visual field loss in adult Chinese in Greater Beijing.MethodsThe Beijing Eye Study 2006 included 3251 subjects (mean age 60.4±10.1 years) who had participated in the Beijing Eye Study 2001 and returned for re-examination. All participants underwent a comprehensive eye examination, including visual field test by frequency doubling threshold perimetry. An abnormal visual field was defined as reduced sensitivity in at least one test location. Incident visual field loss was defined as a change in visual field from normal at baseline to abnormal at follow-up.ResultsAn incident visual field loss was detected in 273 eyes (4.3±0.5%) /235 subjects (7.3±0.5%). It was significantly associated with higher age (P = 0.001), higher intraocular pressure (P<0.001), and higher fasting blood glucose concentration (P = 0.019). Considering only eyes (n = 140) with a detected cause for visual field loss, the most frequent causes were cataract (68 (48.6%) eyes) followed by glaucoma (23 (16.4%) eyes), diabetic retinopathy (13 (9.3%) eyes), age-related macular degeneration (10 (7.1%) eyes), and myopic degenerative retinopathy (9 (6.4%) eyes). For 133 (48.7%) eyes with a visual field loss, the cause for the VFL remained unclear.ConclusionsThe 5-year incidence of visual field loss was 4.3±0.5% per eye or 7.3±0.5% per subject. It increased significantly with age, intraocular pressure, and fasting blood glucose level. Major causes for the incidence of visual field loss were cataract, glaucoma and diabetic retinopathy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.