Background The purpose of this study was to evaluate the ocular biometric parameters in adult cataract patients from China and create an anterior chamber depth (ACD) regression model. Methods The ocular biometric records of 28,709 right eyes of cataract surgery candidates who were treated at Aier Eye Hospitals in nine cities from 2018 to 2019 were retrospectively analyzed. All measurements were taken with IOLMaster 700. We included patients who were at least 40 years old and were diagnosed with cataract. Results The mean age of the patients was 68.6 ± 11.0 years. The mean values recorded were as follows: axial length (AL), 24.17 ± 2.47 mm; mean keratometry (Km) value, 44.26 ± 1.70 D; corneal astigmatism (CA), 1.06 ± 0.96 D; ACD, 3.02 ± 0.45 mm; lens thickness (LT), 4.52 ± 0.45 mm; central corneal thickness (CCT), 0.534 ± 0.04 mm; and white to white (WTW) corneal diameter, 11.64 ± 0.46 mm. ACD correlated positively with AL (Spearman coefficient, 0.544) and WTW (0.300), but negatively with LT (-0.660) and age (-0.285) (all P < 0.01). In the multivariate regression analysis of ACD, which included LT, AL, WTW, sex, Km, CCT, and age, there was a reasonable prediction with adjusted R2 = 0.641. Conclusions Cataract patients with longer AL and wider WTW have deeper ACD. With increasing age and lens thickening ACD becomes shallower. Based on the standardized coefficients of ACD multivariate regression analysis from the study, LT is the main factor that affects ACD, and is followed by AL.
Purpose. To compare the short-term visual outcomes and intraocular optical performance of a rotationally asymmetric multifocal intraocular lens (MIOL) (SBL-3, Lenstec, Inc., Christ Church, Barbados) and an apodized diffractive MIOL (the Acrysof IQ ResTOR SN6AD1, Alcon Laboratories, Inc., Fort Worth, Texas, United States). Methods. A prospective, comparative, nonrandomized, and single-center study. Sixty-eight age-related cataract patients (81 eyes) after phacoemulsification cataract surgery and in-the-bag MIOL implantation were enrolled. Thirty-eight eyes received SBL-3, and 43 eyes received SN6AD1. Ophthalmological evaluation included uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), corrected distance visual acuity (CDVA), modulation transfer function (MTF), Strehl ratio (SR), intraocular aberrations (4 mm optical zone), and defocus curve at 3 months postoperatively. The Chinese version of the visual function index-14 (VF-12-CN) and spectacle independence were assessed in all patients. Results. There was no statistically significant difference between groups in postoperative UDVA (p=0.186). Postoperative UIVA and UNVA were significantly better for the SBL-3 group than for the SN6AD1 group (p<0.01). Statistically significant differences were revealed in defocus levels from –3.50 D to −4.00 D with better visual acuities for the SBL-3 group (p<0.01). For intraocular optical quality outcomes, statistically significant differences between groups were observed in RMS of intraocular total aberrations, coma, and trefoil high-order aberrations, presenting significantly higher values of these parameters in the eyes of the SBL-3 group (p < 0.01). Statistically significant differences were revealed in the MTF values at spatial frequencies of 5 and 10 cycles/degree between groups. There were no significant differences in scores of VF-12-CN, and spectacle independence between the groups (p>0.05). Conclusions. Both MIOLs were able to successfully restore visual function after cataract surgery. SBL-3 provided better UIVA and UNVA with a wider range of intermediate vision.
Background: To create an anterior chamber depth (ACD) regression model for adult cataract surgery candidates from China, and to evaluate the distribution of their ocular biometric parameters.Methods: The ocular biometric records of 28,709 right eyes of cataract surgery candidates who were treated at Aier Eye Hospitals in nine cities from 2018 to 2019 were retrospectively analyzed. All measurements were taken with IOLMaster 700. We included patients who were at least 40 years old and were diagnosed with cataract.Results: The mean age of the patients was 68.6 ± 11.0 years. The mean values recorded were as follows: axial length (AL), 24.17 ± 2.47 mm; mean keratometry (Km) value, 44.09 ± 3.25 D; corneal astigmatism (CA), 1.06 ± 0.98 D; ACD, 3.02 ± 0.45 mm; lens thickness (LT), 4.52 ± 0.45 mm; central corneal thickness (CCT), 0.534 ± 0.04 mm; and white to white (WTW) corneal diameter, 11.64 ± 0.46 mm. The proportion of patients with long axial length (AL >25 mm) decreased with age. ACD, LT, AL, Km, WTW, and age were correlated. In the multivariate regression analysis of ACD, which included LT, AL, WTW, sex, Km, CCT, and age, there was a reasonable prediction with adjusted R2 = 0.629.Conclusions: The results show that high myopes are inclined to schedule cataract surgery at a younger age. LT and AL were found to be important factors that affect ACD. This study provides reference data for cataract patients from China.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.