Magnetic resonance (MR) imaging methods with good spatial and contrast resolution are often too slow to follow the uptake of contrast agents with the desired temporal resolution. Imaging can be accelerated by skipping the acquisition of data normally taken with strong phase-encoding gradients, restricting acquisition to weak-gradient data only. If the usual procedure of substituting zeroes for the missing data is followed, blurring results. Substituting instead reference data taken before or well after contrast agent injection reduces this problem. Volunteer and patient images obtained by using such reference data show that imaging can be usefully accelerated severalfold. Cortical and medullary regions of interest and whole kidney regions were studied, and both gradient- and spin-echo images are shown. The method is believed to be compatible with other acceleration methods such as half-Fourier reconstruction and reading of more than one line of k space per excitation.
Purpose: To assess sensory effects and other health complaints that are reported by system testers working near magnetic resonance imaging (MRI) magnets, realizing that it is believed that exposure up to 8 T is safe for humans.
Materials and Methods:Levels of exposure to static magnetic fields (SMFs), movement speed during exposure, health complaints, and cognitive performance among employees in an MRI-manufacturing department and at a reference department have been analyzed. Mercury concentrations in urine samples were determined to analyze whether they depend on exposure to SMFs.Results: Average exposure of system testers was 25.9 mT/8 hours at a 1.0-T system and 40.4 mT/8 hours at a 1.5-T system. Vertigo, metallic taste, and concentration problems were more reported among workers of MRI-fabrication than in the reference department. Cognitive performance was tested outside the SMF, and no significant changes were detected.
Conclusion:This study suggests that any effects on cognitive functions are acute and transient and disappear rapidly after exposure has ended. All complaints, except for headaches, were more frequently reported by "fast movers" than by "slow movers," and depended on field strength and duration of exposure. Mercury-levels in urine were not affected.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.