Objectives: This research aimed to develop a guideline for evaluating safety and performance of electronic warm-acupuncture apparatus. With the development of medical devices like electronic warm-acupuncture apparatus with improved performance, convenience and safety measures compared to traditional warm-acupuncture needling, safety and performance guideline is a necessity.Methods: By referring to existing standards and guidelines of other electronic devices for Korean medicine with heating function, guideline for safety and performance assessment of electronic warm-acupuncture apparatus was draftedResults: The guideline, presents explanation for adequate temperature and settings of the apparatus, and safety measurements providing against thermal runaway situations along with guidelines for the manual. Guideline for detailed test method for the performance of the apparatus such as accuracy of temperature increase and the timer, and safety unit was also provided. The test items and suggested test methods for the requirements of biological, electrical and electromagnetic safety were referred to Korean approval documents of ministry of Food and Drug Safety.Conclusion: We proposed the relevant items to verify performance and safety of warm-acupuncture apparatus to assure patient safety and improve the quality of currently developing devices for application in clinical field.
Background: Electronic moxibustion (EM) was developed to minimize the side effects of traditional moxibustion, such as burns, and to overcome therapeutic compliances such as smoke or smell. Objectives: To investigate distributions and thermal stimulation of EM at various depths using silicon phantom and to compare this methodology to traditional indirect moxibustion (TIM). Methods: A silicon phantom composed of polydimethylsiloxane was heated and immersed in a hot plate containing warm water to set the phantom's temperature to that of biological tissue. K-type thermocouples were inserted into the phantom at depths of 0, 2, 5, 7, and 10 mm to measure temperature changes with thermal stimulation of EM or TIM placed on top of the phantom. Results: At the surface of the phantom, the peak temperature after applying TIM (55.04 ± 0.92℃ [Δ23.79 ± 0.96℃]) was significantly higher than after EM (43.25 ± 1.95℃ [Δ13.00 ± 2.23℃]), with both interventions reaching the highest temperature after 2 minutes. The temperature increase for TIM was also statistically significant compared to EM when measured at a depth of 2 mm. For the experimental setting with TIM, after reaching peak surface temperature, a rapid decrease was observed at the surface and 2 mm while EM showed a much more gradual decline. There was no significant difference in temperature change between the groups at depths of 5, 7, and 10 mm. Conclusion: TIM resulted in a higher temperature rise compared to EM at the surface and at a 2 mm depth reaching over 50℃, which creates risk of burns. Thermal stimulation with EM had a lower risk of burns with temperature increment not being statistically different from TIM below the depth of 5 mm.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.