Background:Accurate diagnosis is key to success. Diagnosing the pulpal status in varied clinical situations poses a challenge to the clinician. Electric pulp test (EPT) is one of the valuable attempts in evaluating the sensibility of pulp tissue. The aim of this study was to find out and compare the threshold levels and optimal electrode placement site for EPT in fluorosed and nonfluorosed anterior teeth.Materials and Methodology:Eighty volunteers recruited for this study were divided into two groups based on the incidence of dental fluorosis. Electric pulp testing was done on either of the central incisors in fluorosed and nonfluorosed group. Four sites on each crown were tested 4 times with digitest electric pulp tester, and the mean of the threshold responses was recorded. The data were analyzed with SPSS, version 11. Means of variables from each location were compared using one-way ANOVA and Tukey's post-hoc test while the critical level of significance was set at P < 0.05.Results:The mean and standard deviation of threshold levels in fluorosed teeth were greater when compared to that of nonfluorosed teeth at all sites with incisal edge showing the least mean threshold levels for both the groups (P > 0.05).Conclusion:Within the limitations of this study, it can be concluded that fluorosed teeth respond to higher threshold levels than the non-fluorosed teeth, and incisal edge was the optimal electrode placement site.
Introduction: The purpose of this study was to evaluate the sealing ability of three different root canal sealers with and without amoxicillin, using a push-out bond strength test.
Material and Methods:Sixty single-rooted extracted human teeth were used for this study. Each tooth was instrumented and irrigated with 5.25% Sodium hypochlorite (NaOCl) and 17% EDTA. The teeth were then divided into six test groups: Gutta percha (GP)/AH Plus (Dentsply, Germany), GP/AH Plus with 10% amoxicillin (TEVA Pharmaceuticals Sellersville, PA), GP/Pulp Canal Sealer EWT (Extended Working Time, SybronEndo Orange, CA), GP/Pulp Canal Sealer EWT with amoxicillin, GP/Apexit Plus, GP/Apexit Plus (Vivadent, Tulsa, US) with amoxicillin. After the sealer was set, the entire root was sectioned into 1 mm thick slices. A push-out bond strength test was performed by using a universal testing machine. The Student's t-test was used to compare the sealer bond strength within the specific sealer test groups and within each sealer at apical, middle and coronal root levels.Results: There was no significant difference between the groups within each sealer (p>0.05) with or without amoxicillin at the same root level.
Conclusion:This study demonstrated that the addition of 10% by weight of amoxicillin does not significantly (p> 0.05) change the overall push-out bond strength of three endodontic sealers when compared at the apical, middle, and coronal tooth level.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.