Subtracting all reconstructed bone shadows from the original image results in a soft image where lung nodules are no longer obscured by bone shadows. Both the sensitivity and the specificity of experienced radiologists increased.
Background
In oncology, the correct determination of nodal metastatic disease is essential for patient management, as patient treatment and prognosis are closely linked to the stage of the disease. The aim of the study was to develop a tool for automatic 3D detection and segmentation of lymph nodes (LNs) in computed tomography (CT) scans of the thorax using a fully convolutional neural network based on 3D foveal patches.
Methods
The training dataset was collected from the Computed Tomography Lymph Nodes Collection of the Cancer Imaging Archive, containing 89 contrast-enhanced CT scans of the thorax. A total number of 4275 LNs was segmented semi-automatically by a radiologist, assessing the entire 3D volume of the LNs. Using this data, a fully convolutional neuronal network based on 3D foveal patches was trained with fourfold cross-validation. Testing was performed on an unseen dataset containing 15 contrast-enhanced CT scans of patients who were referred upon suspicion or for staging of bronchial carcinoma.
Results
The algorithm achieved a good overall performance with a total detection rate of 76.9% for enlarged LNs during fourfold cross-validation in the training dataset with 10.3 false-positives per volume and of 69.9% in the unseen testing dataset. In the training dataset a better detection rate was observed for enlarged LNs compared to smaller LNs, the detection rate for LNs with a short-axis diameter (SAD) ≥ 20 mm and SAD 5–10 mm being 91.6% and 62.2% (p < 0.001), respectively. Best detection rates were obtained for LNs located in Level 4R (83.6%) and Level 7 (80.4%).
Conclusions
The proposed 3D deep learning approach achieves an overall good performance in the automatic detection and segmentation of thoracic LNs and shows reasonable generalizability, yielding the potential to facilitate detection during routine clinical work and to enable radiomics research without observer-bias.
The authors' results show that the "fast elastic image registration" provides most accurate results with a target registration error of 1.07 ± 0.41 mm at minimum execution times of 11 ± 1 s.
Background: The extent of lung involvement in Coronavirus Disease 2019 (COVID-19) pneumonia, quantified on computed tomography (CT), is an established biomarker for prognosis and guides clinical decision making. The clinical standard is semi-quantitative scoring of lung involvement by an experienced reader. We aim to compare the performance of automated deep-learning-and threshold-based methods to the manual semi-quantitative lung scoring. Further, we aim to investigate an optimal threshold for quantification of involved lung in COVID pneumonia chest CT, using a multi-center dataset.
Methods: In total 250 patients were included, 50 consecutive patients with RT-PCR confirmed COVID-19 from our local institutional database, and another 200 patients from four international datasets (n=50 each). Lung involvement was scored semi-quantitatively by three experienced radiologists according to the established chest CT score (CCS) ranging from 0-25. Inter-rater reliability was reported by the intraclass correlation coefficient (ICC). Deep-learning-based segmentation of ground-glass and consolidation was obtained by CT Pulmo Auto Results prototype plugin on IntelliSpace Discovery (Philips Healthcare, The Netherlands). Threshold-based segmentation of involved lung was implemented using an open-source tool for whole-lung segmentation under the presence of severe pathologies (R231CovidWeb, Hofmanninger et al., 2020) and consecutive quantitative assessment of lung attenuation. The best threshold was investigated by training and testing a linear regression of deep-learning and threshold-based results in a five-fold cross validation strategy. Results: Median CCS among 250 evaluated patients was 10 [6-15]. Inter-rater reliability of the CCS was excellent [ICC 0.97 (0.97-0.98)]. Best attenuation threshold for identification of involved lung was −522 HU.While the relationship of deep-learning-and threshold-based quantification was linear and strong (r 2 deep-learning vs. threshold =0.84), both automated quantification methods translated to the semi-quantitative CCS in a nonlinear fashion, with an increasing slope towards higher CCS (r 2 deep-learning vs. CCS = 0.80, r 2 threshold vs. CCS =0.63).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.