BackgroundPatients with blunt trauma to the liver have elevated levels of liver enzymes within a short time post injury, potentially useful in screening patients for computed tomography (CT). This study was performed to define the optimal cut-off values for serum aspartate aminotransferase (AST) and alanine aminotransferase (ALT) in patients with blunt liver injury diagnosed with contrast enhanced multi detector-row CT (CE-MDCT).MethodsAll patients admitted from May 2006 to July 2013 to Teikyo University Hospital Trauma and Critical Care Center, and who underwent abdominal CE-MDCT within 3 h after blunt trauma, were retrospectively enrolled. Using receiver operating characteristic (ROC) curve analysis, the optimal cut-off values for AST and ALT were defined, and sensitivity and specificity were calculated.ResultsOf a total of 676 blunt trauma patients 64 patients were diagnosed with liver injury (Group LI+) and 612 patients without liver injury (Group LI−). Group LI+ and LI− were comparable for age, Revised Trauma Score, and Probability of survival. The groups differed in Injury Severity Score [median 21 (interquartile range 9–33) vs. 17 (9–26) (p < 0.01)]. Group LI+ had higher AST than LI− [276 (48–503) vs. 44 (16–73); p < 0.001] and higher ALT [240 (92–388) vs. 32 (16–49); p < 0.001]. Using ROC curve analysis, the optimal cut-off values for AST and ALT were set at 109 U/l and 97 U/l, respectively. Based on these values, AST ≥ 109 U/l had a sensitivity of 81 %, a specificity of 82 %, a positive predictive value of 32 %, and a negative predictive value of 98 %. The corresponding values for ALT ≥ 97 U/l were 78, 88, 41 and 98 %, respectively, and for the combination of AST ≥ 109 U/l and/or ALT ≥ 97 U/l were 84, 81, 32, 98 %, respectively.ConclusionsWe have identified AST ≥ 109 U/l and ALT ≥ 97 U/l as optimal cut-off values in predicting the presence of liver injury, potentially useful as a screening tool for CT scan in patients otherwise eligible for observation only or as a transfer criterion to a facility with CT scan capability.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.