The Computational fluid dynamics (CFD) code PHOENICS is applied to simulate and evaluate the combustion process within the furnace of a 1,000 MW dual circle tangential firing single furnace lignite-fired ultra supercritical (USC) boiler. The dependence on overfire air (OFA) positioning on the combustion process is studied. The results show that the highest temperature appears on the upside of the burner zone close to the front wall, and the high temperature zone rises with elevated OFA positions. However, the temperature field distributions are similar despite differing OFA positions. The char content near the rear wall is higher than that near the front wall, and below the furnace arch, coal particles concentrate towards the front wall. Also with elevated OFA positions, nitrogen oxide (NO x ) concentrations at the outlet fall, but char content increases. In regard to NO x emission and char burnout, the suggested optimal distance from the OFA center to the center of the uppermost primary air nozzle should be 6 meters.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.